Difference between revisions of "Drought resilience - Technical solutions"
From Akvopedia
(→Shallow groundwater) |
|||
Line 1: | Line 1: | ||
__NOTOC__ | __NOTOC__ | ||
The list below are technical measures to increase the [[Resilient WASH systems in drought-prone areas|resilience of WASH systems]]. | The list below are technical measures to increase the [[Resilient WASH systems in drought-prone areas|resilience of WASH systems]]. | ||
− | |||
[[Image:infiltration ponds small.jpg|thumb|right|150px|[[Infiltration ponds]]]] | [[Image:infiltration ponds small.jpg|thumb|right|150px|[[Infiltration ponds]]]] | ||
+ | [[Image: bare rock catchment small.jpg|thumb|right|150px|[[Natural rock catchment and Open water reservoir]]]] | ||
+ | [[Image:rainwater harvesting small.jpg|thumb|right|150px|[[Rainwater harvesting]]]] | ||
+ | [[Image:HandDugWell.jpg|thumb|right|150px|[[Traditional hand-dug wells]]]] | ||
+ | ====Surface water: Managed Aquifer Recharge (MAR)==== | ||
* [[Infiltration_ponds|Infiltration ponds]] | * [[Infiltration_ponds|Infiltration ponds]] | ||
* [[Contour trenches|Contour trenches]] | * [[Contour trenches|Contour trenches]] | ||
Line 15: | Line 18: | ||
====Surface water: ground catchment & storage==== | ====Surface water: ground catchment & storage==== | ||
− | |||
− | |||
*[[Natural rock catchment and Open water reservoir]] | *[[Natural rock catchment and Open water reservoir]] | ||
*[[Natural or artificial ground catchment and Lined sub-surface tanks|Natural or artificial ground catchment and Lined sub-surface tanks]] | *[[Natural or artificial ground catchment and Lined sub-surface tanks|Natural or artificial ground catchment and Lined sub-surface tanks]] | ||
Line 24: | Line 25: | ||
====Surface water: other catchment & storage==== | ====Surface water: other catchment & storage==== | ||
− | |||
− | |||
*[[Rainwater harvesting|Rooftop rainwater harvesting]] | *[[Rainwater harvesting|Rooftop rainwater harvesting]] | ||
*[[Dew collection and storage]] | *[[Dew collection and storage]] | ||
Line 32: | Line 31: | ||
====Shallow groundwater==== | ====Shallow groundwater==== | ||
− | |||
− | |||
*[[Dug wells|Traditional hand-dug wells]] | *[[Dug wells|Traditional hand-dug wells]] | ||
*[[Riverbed hand-dug wells]] | *[[Riverbed hand-dug wells]] |
Revision as of 20:32, 5 June 2012
The list below are technical measures to increase the resilience of WASH systems.
Surface water: Managed Aquifer Recharge (MAR)
- Infiltration ponds
- Contour trenches
- Bunds
- Gully plugs / check-dams
- Leaky dams
- Controlled flooding / irrigation
- Drip irrigation
- Well shafts & boreholes
Surface water: ground catchment & storage
- Natural rock catchment and Open water reservoir
- Natural or artificial ground catchment and Lined sub-surface tanks
- Natural ground catchment and Open water reservoir
- Catchment and storage dams
Surface water: other catchment & storage
Shallow groundwater
- Traditional hand-dug wells
- Riverbed hand-dug wells
- Riverbed infiltration galleries
- Infiltration wells
- Spring water sources
- Groundwater - Sand_dam
- Controlled flooding / Spreading basins
- Subsurface harvesting systems