<small-title />
<!-- table at top of page with logo, picture, Application level, Management level, and input-output tables -->
{|width="100%"
|}
<br>
----
<br>
[[Image:Icon_leach_field.png |right|95px80px]]
'''A Leach Field, or drainage field, is a network perforated pipes that are laid in underground gravel-filled trenches to dissipate the effluent froma water-based Collection and Storage/Treatment or (Semi-) Centralized Treatment technology.'''
Effluent is fed into a distribution box which directs the flow into several parallel channels. A small dosing system releases the pressurized effluent into the Leach Field on a timer (usually 3 to 4 times a day). This ensures that the whole length of the Leach Field is utilized and that aerobic conditions are allowed to recover between dosings. Each trench is 0.3 to 1.5m deep and 0.3 to 1m wide. The bottom of each trench is filled with about 15cm of clean rock and a perforated distribution pipe is laid overtop. More rock covers the pipe so that it is completely surrounded. The layer of rock is covered with a layer of geotextile fabric to prevent small particles from plugging the pipe. A final layer of sand and/or topsoil covers the fabric and fills the trench to the ground level. The pipe should be placed 15cm from the surface to prevent effluent from surfacing. The trenches should be dug no longer than 20m in length at least 1 to 2m apart.
<br>
{{procontable | pro=
- Can be used for the combined treatment of blackwater and greywater. <br> - Has a lifespan of 20 or more years (depending on conditions). <br> - Low to moderate capital cost, low operating cost. | con=
}}
<br>===Adequacy===
Leach Fields require a large area and soil with good absorptive capacity to effectively dissipate the effluent.
Homeowners who have a Leach Field must be aware of how it works and what their maintenance responsibilities are. Trees and deep-rooted plants should be kept away from the Leach Field as they can crack and disturb the tile bed.
===Health Aspects/Acceptance===
Since the technology is underground and it requires little attention, users will rarely come in contact with the effluent and so it should pose no health risk. The Leach Field must be kept as far away as possible from (>30m) any potential potable water sources to avoid contamination.
===Upgrading===
A Leach Field should be laid out such that it would not interfere with a future sewer connection. The collection technology which precedes the Leach Field (e.g. [[Septic Tank]]) should be equipped with a sewer connection so that if, or when, the Leach Field needs to be replaced, the changeover can be done with minimal disruption.
===Maintenance===
A Leach Field will become clogged over time, although with a well-functioning pre-treatment technology, this should take many years. Effectively, a Leach Field should require minimal maintenance, however if the system stops working efficiently, the pipes should be cleaned and/or removed and replaced. To maintain the Leach Field, there should be no plants or trees above it and no heavy traffic, which may crush the pipes or compact the soil.
===References===
* Crites, R. and Tchobanoglous, G. (1998). [http://books.google.com/books/about/Small_and_decentralized_wastewater_manag.html?id=yx9SAAAAMAAJ Small and Decentralized Wastewater Management Systems]. WCB and McGraw-Hill, New York, USA. pp 905–927.
* [http://www.epa.gov USEPA] (1980). [http://www.epa.gov/nrmrl/pubs/625180012.html Design manual- on-site wastewater treatment and disposal systems. EPA-625/1-80-012]. Office of Research and Development, Municipal Environmental Research Laboratory, Cincinnati, Ohio.
===Acknowledgements===
{{:Acknowledgements Sanitation}}