Difference between revisions of "Activated Sludge"

From Akvopedia
Jump to: navigation, search
(References)
 
(13 intermediate revisions by 3 users not shown)
Line 1: Line 1:
<!-- table at top of page with logo, picture, Application level, Management level, and input-output tables -->
+
{|style="float: left;"
{{santable|
+
|{{Language-box|english_link=Activated_Sludge|french_link=Boues_activés|spanish_link=Lodo_Activado|hindi_link=coming soon|malayalam_link=coming soon|tamil_link=coming soon | korean_link=coming soon chinese_link=Coming soon | indonesian_link=Coming soon | japanese_link=Coming soon }}
 +
|}
 +
{|width="100%"
 +
|style="width:50%;"|{{santable_new|
 
sys1=[[Single Pit System |1]]|
 
sys1=[[Single Pit System |1]]|
sys2=[[Blackwater Treatment System with Infiltration|5]]|
+
sys2=[[Blackwater Treatment System with Infiltration|6]]|
sys3=[[Blackwater Treatment System with Sewerage|6]]|
+
sys3=[[Blackwater Treatment System with Effluent Transport|7]]|
sys4=[[(Semi-) Centralized Treatment System |7]]|
+
sys4=[[Blackwater Transport to (Semi-) Centralized Treatment System |8]]|
sys5=|  
+
sys5=[[Sewerage System with Urine Diversion|9]]|  
 
sys6=|
 
sys6=|
 
sys7=|
 
sys7=|
 
sys8=|
 
sys8=|
 +
sys9=|
 
pic=Activated_sludge.png|
 
pic=Activated_sludge.png|
 
ApplHousehold=|
 
ApplHousehold=|
Line 16: Line 20:
 
ManShared=|
 
ManShared=|
 
ManPublic=XX|
 
ManPublic=XX|
Input1=Blackwater|Input2=Greywater |Input3= | Input4= |Input5=|
+
Input1=Blackwater|Input2=Greywater |Input3=Brownwater | Input4=Effluent |Input5=|
Output1= Effluent | Output2= Treated Sludge | Output3= | Output4= | Output5=
+
Output1= Effluent | Output2= Sludge | Output3= | Output4= | Output5=
 
}}
 
}}
 +
|[[Image:Activated_sludge.png |right|500px]]
 +
|}
 +
<br>
 +
----
 +
<br>
  
[[Image:Icon_activated_sludge.png |right|95px]]
+
[[Image:Icon_activated_sludge.png |right|80px]]
'''Activated Sludge is a multi-chamber reactor unit that makes use of (mostly) aerobic microorganisms to degrade organics in wastewater and to produce a high-quality effluent. To maintain aerobic conditions and to the keep the active biomass suspended, a constant and well-timed supply of oxygen is required.'''
 
  
Different configurations of the Activated Sludge process can be employed to ensure that the wastewater is mixed and aerated (with either air or pure oxygen) in an aeration tank. The microorganisms oxidize the organic carbon in the wastewater to produce new cells, carbon dioxide and water. Although aerobic bacteria are the most common organisms, aerobic, anaerobic, and/or nitrifying bacteria along with higher organisms can be present. The exact composition depends on the reactor design, environment, and wastewater characteristics. During aeration and mixing, the bacteria form small clusters, or flocs. When the aeration stops, the mixture is transferred to a secondary clarifier where the flocs are allowed to settle out and the effluent moves on for further treatment or discharge. The sludge is then recycled back to the aeration tank, where the process is repeated.
+
'''An activated sludge process refers to a multi-chamber reactor unit that makes use of highly concentrated microorganisms to degrade organics and
 +
remove nutrients from wastewater to produce a high-quality effluent. To maintain aerobic conditions and to keep the activated sludge suspended, a continuous and well-timed supply of oxygen is required.'''
  
To achieve specific effluent goals for BOD, nitrogen and phosphorus, different adaptations and modifications have been made to the basic Activated Sludge design. Aerobic conditions, nutrient-specific organisms (especially for phosphorus), recycle design and carbon dosing, among others, have successfully allowed Activated Sludge processes to achieve high treatment efficiencies.
+
<br>
 +
Different configurations of the activated sludge process can be employed to ensure that the wastewater is mixed and aerated in an aeration tank. Aeration and mixing can be provided by pumping air or oxygen into the tank or by using surface aerators. The microorganisms oxidize the organic carbon in the wastewater to produce new cells, carbon dioxide and water. Although aerobic bacteria are the most common organisms, facultative bacteria along with higher organisms can be present.
  
 +
The exact composition depends on the reactor design, environment, and wastewater characteristics. The flocs (agglomerations of sludge particles), which form in the aerated tank, can be removed in the secondary clarifier by gravity settling. Some of this sludge is recycled from the clarifier back to the reactor. The effluent can be discharged or treated in a tertiary treatment facility if necessary for further use.
 +
 +
===Design Considerations===
 +
Activated sludge processes are one part of a complex treatment system. They are usually used after primary treatment (that removes settleable solids) and are sometimes followed by a final polishing step (see POST, p.136). The biological processes that occur are effective at removing soluble, colloidal and particulate materials. The reactor can be designed for biological nitrification and denitrification, as well as for biological phosphorus removal. The design must be based on an accurate estimation of the wastewater composition and volume. Treatment efficiency can be severely compromised if the plant is under- or over-dimensioned. Depending on the temperature, the solids retention time (SRT) in the reactor ranges from 3 to 5 days for BOD removal, to 3 to 18 days for nitrification.
 +
 +
The excess sludge requires treatment to reduce its water and organic content and to obtain a stabilized product suitable for end-use or final disposal. It is
 +
important to consider this step in the planning phase of the treatment plant. To achieve specific effluent goals for BOD, nitrogen and phosphorus, different adaptations and modifications have been made to the basic activated sludge design. Well known modifications include sequencing batch reactors (SBR), oxidation ditches, extended aeration, moving beds and membrane bioreactors.
 +
 +
<br>
 
{{procontable | pro=
 
{{procontable | pro=
- Good resistance against shock loading. <br> - Can be operated at a range of organic and hydraulic loading rates. High reduction of BOD and pathogens (up to 99%). <br> - Can be modified to meet specific discharge limits. | con=
+
- Resistant to organic and hydraulic shock loads <br>
- Prone to complicated chemical and microbiological problems. <br> - Effluent might require further treatment/ disinfection before discharge. <br> - Not all parts and materials may be available locally. <br> - Requires expert design and supervision. <br> - High Capital cost; high operation cost. <br> - Constant source of electricity is required. <br> - Effluent and sludge require secondary treatment and/or appropriate discharge.
+
- Can be operated at a range of organic and hydraulic loading rates <br>
 +
- High reduction of BOD and pathogens (up to 99%) <br>
 +
- High nutrient removal possible <br>
 +
- Can be modified to meet specific discharge limits
 +
| con=
 +
- High energy consumption, a constant source of electricity is required <br>
 +
- High capital and operating costs <br>
 +
- Requires operation and maintenance by skilled personnel <br>
 +
- Prone to complicated chemical and microbiological problems <br>
 +
- Not all parts and materials may be locally available <br>
 +
- Requires expert design and construction <br>
 +
- Sludge and possibly effluent require further treatment and/or appropriate discharge
 
}}
 
}}
  
==Adequacy==
+
===Appropriateness===  
 
+
An activated sludge process is only appropriate for a Centralized Treatment facility with a well-trained staff, constant electricity and a highly developed management system that ensures that the facility is correctly operated and maintained. Because of economies of scale and less fluctuating influent characteristics, this technology is more effective for the treatment of large volumes of flows. An activated sludge process is appropriate in almost every climate. However, treatment capacity is reduced in colder environments.
Activated Sludge is only appropriate for a centralized treatment facility with a well-trained staff, constant electricity and a highly developed centralized management system to ensure that the facility is operated and maintained correctly.
 
 
 
Activated Sludge processes are one part of a complex treatment system. They are used following primary treatment (that removes settleable solids) and before a final polishing step. The biological processes that occur are effective at removing soluble, colloidal and particulate organic materials for biological nitrification and denitrification and for biological phosphorus removal. This technology is effective for the treatment of large volumes of flows: 10,000 to 1,000,000 people.
 
  
Highly trained staff is required for maintenance and trouble-shooting. The design must be based on an accurate estimation of the wastewater composition and volume.
+
===Health Aspects/Acceptance===
 +
Because of space requirements and odours, Centralized Treatment facilities are generally located in the periphery of densely populated areas. Although the effluent produced is of high quality, it still poses a health risk and should not be directly handled. In the excess sludge pathogens are substantially reduced, but not eliminated.
  
Treatment efficiency can be severely compromised if the plant is under- or over- designed. An Activated Sludge process is appropriate for almost every climate.
+
===Operation & Maintenance===
 +
Highly trained staff is required for maintenance and troubleshooting. The mechanical equipment (mixers, aerators and pumps) must be constantly maintained. As well, the influent and effluent must be constantly monitored and the control parameters adjusted, if necessary, to avoid abnormalities that could kill the active biomass and the development of detrimental organisms which could impair the process (e.g., filamentous bacteria).
  
==Health Aspects/Acceptance==
+
===References===
 +
* Crites, R. and Tchobanoglous, G. (1998). Small and Decentralized Wastewater Management Systems. WCB/McGraw- Hill, New York, US. pp. 451-504. (Book; Comprehensive summary including solved problems)
  
Because of space requirements, Centralized treatment facilities are generally located away from the densely populated areas that they serve. Although the effluent produced is of high quality, it still poses a health risk and should not be handled directly.
+
* Ludwig, H. F. and Mohit, K. (2000). Appropriate Technology for Municipal Sewerage/Excreta Management in Developing Countries, Thailand Case Study. The Environmentalist 20 (3): 215-219. (Assessment of the appropriateness of activated sludge for Thailand)
  
==Maintenance==
+
* von Sperling, M. and de Lemos Chernicharo, C. A. (2005). [https://www.iwapublishing.com/sites/default/files/ebooks/9781780402734.pdf Biological Wastewater Treatment in Warm Climate Regions, Volume Two]. IWA Publishing, London, UK.
  
The mechanical equipment (mixers, aerators and pumps) must be maintained constantly. As well, the influent and effluent must be monitored constantly to ensure that there are no abnormalities that could kill the active biomass and to ensure that detrimental organisms have not developed that could impair the process (e.g. filamentous bacteria).
+
*Tchobanoglous, G., Burton, F. L. and Stensel, H. D. (2004). Wastewater Engineering: Treatment and Reuse, Metcalf & Eddy, 4th Ed. (Internat. Ed.). McGraw-Hill, New York, US. (Detailed design information)
  
==Acknowledgements==
+
===Acknowledgements===
 
{{:Acknowledgements Sanitation}}
 
{{:Acknowledgements Sanitation}}
 
==References and external links==
 
 
* Crites, R. and Tchobanoglous, G. (1998). Small and Decentralized Wastewater Management Systems. WCB and McGraw-Hill, New York, USA. pp 451–504. (Comprehensive summary including solved problems.)
 
 
* Ludwig, HF. and Mohit, K. (2000). Appropriate technology for municipal sewerage/Excreta management in developing countries, Thailand case study. The Environmentalist 20(3): 215–219. (Assessment of the appropriateness of Activated Sludge for Thailand.)
 
 
* von Sperling, M. and de Lemos Chernicharo, CA. (2005). Biological Wastewater Treatment in Warm Climate Regions, Volume Two. IWA, London.
 
 
* Tchobanoglous, G., Burton, FL. and Stensel, HD. (2003). Wastewater Engineering: Treatment and Reuse, 4th Edition. Metcalf & Eddy, New York.
 

Latest revision as of 20:27, 1 November 2020

English Français Español भारत മലയാളം தமிழ் 한국어 Indonesia Japanese
Applicable in systems:
1, 6 , 7 , 8 , 9
Level of Application
Household
Neighbourhood X
City XX

 

Inputs
Blackwater, Greywater, Brownwater, Effluent


Level of management
Household
Shared
Public XX

 

Outputs
Effluent, Sludge
Activated sludge.png




Icon activated sludge.png

An activated sludge process refers to a multi-chamber reactor unit that makes use of highly concentrated microorganisms to degrade organics and remove nutrients from wastewater to produce a high-quality effluent. To maintain aerobic conditions and to keep the activated sludge suspended, a continuous and well-timed supply of oxygen is required.


Different configurations of the activated sludge process can be employed to ensure that the wastewater is mixed and aerated in an aeration tank. Aeration and mixing can be provided by pumping air or oxygen into the tank or by using surface aerators. The microorganisms oxidize the organic carbon in the wastewater to produce new cells, carbon dioxide and water. Although aerobic bacteria are the most common organisms, facultative bacteria along with higher organisms can be present.

The exact composition depends on the reactor design, environment, and wastewater characteristics. The flocs (agglomerations of sludge particles), which form in the aerated tank, can be removed in the secondary clarifier by gravity settling. Some of this sludge is recycled from the clarifier back to the reactor. The effluent can be discharged or treated in a tertiary treatment facility if necessary for further use.

Design Considerations

Activated sludge processes are one part of a complex treatment system. They are usually used after primary treatment (that removes settleable solids) and are sometimes followed by a final polishing step (see POST, p.136). The biological processes that occur are effective at removing soluble, colloidal and particulate materials. The reactor can be designed for biological nitrification and denitrification, as well as for biological phosphorus removal. The design must be based on an accurate estimation of the wastewater composition and volume. Treatment efficiency can be severely compromised if the plant is under- or over-dimensioned. Depending on the temperature, the solids retention time (SRT) in the reactor ranges from 3 to 5 days for BOD removal, to 3 to 18 days for nitrification.

The excess sludge requires treatment to reduce its water and organic content and to obtain a stabilized product suitable for end-use or final disposal. It is important to consider this step in the planning phase of the treatment plant. To achieve specific effluent goals for BOD, nitrogen and phosphorus, different adaptations and modifications have been made to the basic activated sludge design. Well known modifications include sequencing batch reactors (SBR), oxidation ditches, extended aeration, moving beds and membrane bioreactors.


Advantages Disadvantages/limitations
- Resistant to organic and hydraulic shock loads

- Can be operated at a range of organic and hydraulic loading rates
- High reduction of BOD and pathogens (up to 99%)
- High nutrient removal possible
- Can be modified to meet specific discharge limits

- High energy consumption, a constant source of electricity is required

- High capital and operating costs
- Requires operation and maintenance by skilled personnel
- Prone to complicated chemical and microbiological problems
- Not all parts and materials may be locally available
- Requires expert design and construction
- Sludge and possibly effluent require further treatment and/or appropriate discharge


Appropriateness

An activated sludge process is only appropriate for a Centralized Treatment facility with a well-trained staff, constant electricity and a highly developed management system that ensures that the facility is correctly operated and maintained. Because of economies of scale and less fluctuating influent characteristics, this technology is more effective for the treatment of large volumes of flows. An activated sludge process is appropriate in almost every climate. However, treatment capacity is reduced in colder environments.

Health Aspects/Acceptance

Because of space requirements and odours, Centralized Treatment facilities are generally located in the periphery of densely populated areas. Although the effluent produced is of high quality, it still poses a health risk and should not be directly handled. In the excess sludge pathogens are substantially reduced, but not eliminated.

Operation & Maintenance

Highly trained staff is required for maintenance and troubleshooting. The mechanical equipment (mixers, aerators and pumps) must be constantly maintained. As well, the influent and effluent must be constantly monitored and the control parameters adjusted, if necessary, to avoid abnormalities that could kill the active biomass and the development of detrimental organisms which could impair the process (e.g., filamentous bacteria).

References

  • Crites, R. and Tchobanoglous, G. (1998). Small and Decentralized Wastewater Management Systems. WCB/McGraw- Hill, New York, US. pp. 451-504. (Book; Comprehensive summary including solved problems)
  • Ludwig, H. F. and Mohit, K. (2000). Appropriate Technology for Municipal Sewerage/Excreta Management in Developing Countries, Thailand Case Study. The Environmentalist 20 (3): 215-219. (Assessment of the appropriateness of activated sludge for Thailand)
  • Tchobanoglous, G., Burton, F. L. and Stensel, H. D. (2004). Wastewater Engineering: Treatment and Reuse, Metcalf & Eddy, 4th Ed. (Internat. Ed.). McGraw-Hill, New York, US. (Detailed design information)

Acknowledgements

Eawag compendium cover.png

The material on this page was adapted from:

Elizabeth Tilley, Lukas Ulrich, Christoph Lüthi, Philippe Reymond and Christian Zurbrügg (2014). Compendium of Sanitation Systems and Technologies, published by Sandec, the Department of Water and Sanitation in Developing Countries of Eawag, the Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.