{{Language-box|english_link= Elevated storage tanks | french_link= Coming soon | spanish_link= Coming soon | hindi_link= Coming soon | malayalam_link= Coming soon | tamil_link= Coming soon | swahili_link=coming soon | korean_link= Coming soon | chinese_link=Coming soon | indonesian_link= Coming soon | japanese_link= Coming soon }}
 +
 
Elevated tanks do not require the continuous operation of pumps, as it will not affect the distribution system since the pressure is maintained by gravity. Strategic location of the tank can equalize water pressures in the distribution system.  However, precise water pressure can be difficult to manage in some elevated tanks.   
 
Elevated tanks do not require the continuous operation of pumps, as it will not affect the distribution system since the pressure is maintained by gravity. Strategic location of the tank can equalize water pressures in the distribution system.  However, precise water pressure can be difficult to manage in some elevated tanks.   
<small-title />
+
 
 
The pressure of the water flowing out of an elevated tank depends on the depth of the water in the tank.  A nearly empty tank probably will not provide enough pressure while a completely full tank may provide too much pressure.  The optimal pressure is achieved at only one depth (which is even more specific for standpipes than for tanks elevated on legs). The length of the standpipe causes continual and highly unequal pressures on the distribution system. In addition, a significant quantity of the water in a standpipe is required to produce the necessary water pressure.  The water below a certain level is therefore used only as a support, unless booster pumps are available for emergency use of this water.   
 
The pressure of the water flowing out of an elevated tank depends on the depth of the water in the tank.  A nearly empty tank probably will not provide enough pressure while a completely full tank may provide too much pressure.  The optimal pressure is achieved at only one depth (which is even more specific for standpipes than for tanks elevated on legs). The length of the standpipe causes continual and highly unequal pressures on the distribution system. In addition, a significant quantity of the water in a standpipe is required to produce the necessary water pressure.  The water below a certain level is therefore used only as a support, unless booster pumps are available for emergency use of this water.   
  
Line 42: Line 44:
 
* [http://www.teamlandmark.com/water_storage/composite_elevated_tank/cost_advantage Cost advantage of the composite elevated tank.] Landmark.
 
* [http://www.teamlandmark.com/water_storage/composite_elevated_tank/cost_advantage Cost advantage of the composite elevated tank.] Landmark.
 
* [http://www.ehow.com/list_6022500_advantages-elevated-water-towers.html#ixzz1A2MOrfjt Advantages for Elevated Water Towers.] By Dennis Hartman, eHow Contributor.
 
* [http://www.ehow.com/list_6022500_advantages-elevated-water-towers.html#ixzz1A2MOrfjt Advantages for Elevated Water Towers.] By Dennis Hartman, eHow Contributor.
* [http://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=12&ved=0CEoQFjABOAo&url=http%3A%2F%2Fwww.caldwellwatertanks.com%2Fdownloads%2Fwater_quality%2Fwater_quality_of_elev_tanks.pdf&ei=Hpu9T5WMDvLUiAKD9Zn8Aw&usg=AFQjCNG3uHT86lfGlp90vFTV1NHAyeCsFw&sig2=uVSzmIsWvrhBGap8Zh9hsg Mitigating the Impacts of Elevated Water Storage Tanks on Water Quality.] Stantec Inc.
+
* [http://www.caldwellwatertanks.com/downloads/water_quality/water_quality_of_elev_tanks.pdf Mitigating the Impacts of Elevated Water Storage Tanks on Water Quality.] Stantec Inc.
  
 
===Acknowledgements===
 
===Acknowledgements===
 
* [http://water.me.vccs.edu/courses/env110/lesson10.htm Lesson 10: Water Tank Design and Maintenance.] Mountain Empire Community College.
 
* [http://water.me.vccs.edu/courses/env110/lesson10.htm Lesson 10: Water Tank Design and Maintenance.] Mountain Empire Community College.

Revision as of 01:36, 10 January 2017

English Français Español भारत മലയാളം தமிழ் Swahili 한국어 中國 Indonesia Japanese

Elevated tanks do not require the continuous operation of pumps, as it will not affect the distribution system since the pressure is maintained by gravity. Strategic location of the tank can equalize water pressures in the distribution system. However, precise water pressure can be difficult to manage in some elevated tanks.

The pressure of the water flowing out of an elevated tank depends on the depth of the water in the tank. A nearly empty tank probably will not provide enough pressure while a completely full tank may provide too much pressure. The optimal pressure is achieved at only one depth (which is even more specific for standpipes than for tanks elevated on legs). The length of the standpipe causes continual and highly unequal pressures on the distribution system. In addition, a significant quantity of the water in a standpipe is required to produce the necessary water pressure. The water below a certain level is therefore used only as a support, unless booster pumps are available for emergency use of this water.

While elevated tanks provide the best pressure, they are far-more expensive and generally, only used where supply is in high demand.


Reinforced concrete reservoir small.jpg
Elevated steel reservoir small.jpg
250px-Commercial elevated tanks small.jpg
Elevated plastic small.png


Field experiences

The following project(s) is utilizing an elevated tank.

Akvorsr logo lite.png
RSR Project 822
Urban WASH II
in Monrovia


Elevated storage tanks links

Acknowledgements