River-bottom intake mechanics.
Click image to zoom.

River-bottom or Tyrolean intakes for drinking-water systems are usually used in small rivers and streams where the sediment content and bed load transport are low. The water is abstracted through a screen over a canal (usually made of concrete and built into the river bed). The bars of the screen are laid in the direction of the current and sloping downwards, so that coarse material can- not enter. From the canal, water enters a sand trap and then may pass a valve and flow by gravity, or be pumped into the rest of the system.

Intake designs aim to avoid clogging and scouring and to ensure the stability of the structure even under flood conditions. Where the river transports no boulders or rolling stones, an unprotected intake may be adequate.

Suitable conditions

  • Rivers with little sediment and bed load.
  • Where there is adequate flow.
  • At a level that allows gravity supply to minimise pumping costs.
  • Upstream of densely populated and farming areas to reduce silt inflow.
  • Upstream of cattle watering places, washing places and sewer outlets (to eliminate pollution of the water).
  • Upstream of bridges (to reduce velocity/turbulence).

Construction, operations and maintenance

The bottom of the intake structure should be at least 1m above the riverbed to prevent any boulders or rolling stones from entering. The intake structure must always include one or more baffles or screens to keep out debris and floating matter such as tree trunks and branches. It is advisable to use “passive” screening that does not create turbulent flow conditions. To reduce the drawing in of silt and suspended matter, the velocity of flow through the intake should be low, preferably less than 0.1 m/s. To make use of the natural current to help cleaning of screens, the following tips are suggested:

  • The screen axis must be parallel to the current flow
  • Dead-end approach channels should be avoided as they collect debris
  • Adequate water cover must be provided all around the screen