488 bytes added, 00:43, 23 October 2012
no edit summary
====India Mark lll pump====
==Suitable conditions==
 
{|border="1" cellpadding="5"
|-
|Depths for use:
|between 50 - 80 m
|-
|Cylinder diameter:
|63.5 mm
|-
|Maximum Stroke:
|125 mm
|-
|Approx. discharge (75 watt input):
|at 50 m head: 0.55 m³/hour<br>
at 60 m head: 0.45 m³/hour<br>
at 70 m head: 0.4 m³/hour<br>
at 80 m head: 0.35 m³/hour
|-
|Population served:
|up to 150 people
|-
|Households:
|10 – 15 households
|-
|Assumed water consumption:
|15 - 20 l/per capita
|-
|Type of well:
|borehole
|}
 
==Construction, operations and maintenance==
[[Image:India Mark ll tools.jpg|thumb|right|250px|The India Mark ll pump toolkit. Photo: [http://www.clean-water-for-laymen.com/water-hand-pumps.html A Layman's Guide to Clean Water.]]]
Akvopedia-spade, akvouser, bureaucrat, emailconfirmed, staff, susana-working-group-1, susana-working-group-10, susana-working-group-11, susana-working-group-12, susana-working-group-2, susana-working-group-3, susana-working-group-4, susana-working-group-5, susana-working-group-6, susana-working-group-7, susana-working-group-8, susana-working-group-9, susana-working-group-susana-member, administrator, widget editor