Difference between revisions of "Bush pump"

From Akvopedia
Jump to: navigation, search
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
[[Image:lever action icon.png|right|100px]]
+
{{Language-box|english_link= Bush pump | french_link= Coming soon | spanish_link= Coming soon | hindi_link= Coming soon | malayalam_link= Coming soon | tamil_link= Coming soon | swahili_link=coming soon | korean_link= Coming soon | chinese_link=津巴布韦水泵 | indonesian_link= Coming soon | japanese_link= Coming soon }}
 +
 
 +
[[Image:lever action icon.png|right|80px]]
 +
[[Image:bush pump.jpg|thumb|right|200px|The Bush pump used a lot in Zimbabwe. Photo: [http://www.rural-water-supply.net/en/implementation/handpump-overview/bush-pump RWSN.]]]  
  
[[Image:bush pump.jpg|thumb|right|250px|The Bush pump used a lot in Zimbabwe. Photo: [http://www.rural-water-supply.net/en/implementation/handpump-overview/bush-pump RWSN.]]]
 
__NOTOC__
 
 
The Bush Pump is a robust conventional lever action handpump, developed and standardised in Zimbabwe (SAZ 881:2004). It is designed for heavy-duty use, serving communities of 300 persons.  
 
The Bush Pump is a robust conventional lever action handpump, developed and standardised in Zimbabwe (SAZ 881:2004). It is designed for heavy-duty use, serving communities of 300 persons.  
  
 
The typical feature of this pump is the “Hardwood block” that acts as both, bearing and lever mechanism. The pump is designed that the stand can be directly bolted to the protruding 6” steel casing of the borehole, Ø150 mm NB (Nominal Bore).Three different cylinders are available, the smallest one extend the range to a maximum recommended lift of 80 m. The Bush Pump is not corrosion resistant. It requires special skills for installation as well as for the maintenance; it is not a VLOM pump.
 
The typical feature of this pump is the “Hardwood block” that acts as both, bearing and lever mechanism. The pump is designed that the stand can be directly bolted to the protruding 6” steel casing of the borehole, Ø150 mm NB (Nominal Bore).Three different cylinders are available, the smallest one extend the range to a maximum recommended lift of 80 m. The Bush Pump is not corrosion resistant. It requires special skills for installation as well as for the maintenance; it is not a VLOM pump.
  
==Suitable conditions==
+
===Suitable conditions===
[[Image:bush pump2.jpg|thumb|right|250px|The Bush pump can be locally manufactured. Photo: [http://www.rural-water-supply.net/en/implementation/handpump-overview/bush-pump RWSN.]]]  
+
[[Image:bush pump2.jpg|thumb|right|200px|The Bush pump can be locally manufactured. Photo: [http://www.rural-water-supply.net/en/implementation/handpump-overview/bush-pump RWSN.]]]  
  
 
Distribution: More than 30,000 in Zimbabwe.
 
Distribution: More than 30,000 in Zimbabwe.
Line 49: Line 50:
  
  
==Construction, operations and maintenance ==
+
===Construction, operations and maintenance ===
  
 
Pump stand is made of mild steel painted, handle & riser pipes of galvanized GI pipe, pump rods are of galvanized steel, cylinder of brass, bearing block of hardwood, plunger and foot valve of bronze or brass. This pump is not corrosion resistant and should not be used in areas with aggressive water (pH < 6.5).
 
Pump stand is made of mild steel painted, handle & riser pipes of galvanized GI pipe, pump rods are of galvanized steel, cylinder of brass, bearing block of hardwood, plunger and foot valve of bronze or brass. This pump is not corrosion resistant and should not be used in areas with aggressive water (pH < 6.5).
Line 59: Line 60:
 
The pump with the standard configuration has a limited “Community Management Potential”, but it is very reliable and popular with the community. Besides the “Standard” configuration, there exists an “Open Top Cylinder” version (easier to maintain) with different cylinder sizes (Ø50 mm, Ø63.5 mm and Ø75 mm). To make maintenance easy, pump rods with case-hardened hook & eye connectors, are standard (Ø16 mm).
 
The pump with the standard configuration has a limited “Community Management Potential”, but it is very reliable and popular with the community. Besides the “Standard” configuration, there exists an “Open Top Cylinder” version (easier to maintain) with different cylinder sizes (Ø50 mm, Ø63.5 mm and Ø75 mm). To make maintenance easy, pump rods with case-hardened hook & eye connectors, are standard (Ø16 mm).
  
==Manuals, videos, and links==
+
===Manuals, videos and links===
 
* ERPF, K. [http://docs.watsan.net/Downloaded_Files/PDF/Erpf-1998-Bushpump.pdf The Bush Pump - the national Standard Handpump of Zimbabwe] or ([http://www.rural-water-supply.net/en/resources/details/216 alternative link]). A review by SKAT/HTN to find out what had made this pump so popular in Zimbabwe. Skat , RWSN (incl. HTN), St Gallen, Switzerland. 1998.
 
* ERPF, K. [http://docs.watsan.net/Downloaded_Files/PDF/Erpf-1998-Bushpump.pdf The Bush Pump - the national Standard Handpump of Zimbabwe] or ([http://www.rural-water-supply.net/en/resources/details/216 alternative link]). A review by SKAT/HTN to find out what had made this pump so popular in Zimbabwe. Skat , RWSN (incl. HTN), St Gallen, Switzerland. 1998.
  
Line 68: Line 69:
 
* RWSN/DWRD [http://www.rural-water-supply.net/en/resources/details/323 Bush Pump. Zimbabwe Standard Specification], Department of Water Resources and Development , The Zimbabwe Government, Harare, Zimbabwe. 2004.
 
* RWSN/DWRD [http://www.rural-water-supply.net/en/resources/details/323 Bush Pump. Zimbabwe Standard Specification], Department of Water Resources and Development , The Zimbabwe Government, Harare, Zimbabwe. 2004.
  
==Acknowledgements==
+
===Acknowledgements===
 
* [http://www.rural-water-supply.net/en/implementation/handpump-overview/bush-pump Implementation • Handpump Technology Bush Pump]. RWSN.
 
* [http://www.rural-water-supply.net/en/implementation/handpump-overview/bush-pump Implementation • Handpump Technology Bush Pump]. RWSN.

Latest revision as of 01:08, 19 April 2017

English Français Español भारत മലയാളം தமிழ் Swahili 한국어 中國 Indonesia Japanese
Lever action icon.png
The Bush pump used a lot in Zimbabwe. Photo: RWSN.

The Bush Pump is a robust conventional lever action handpump, developed and standardised in Zimbabwe (SAZ 881:2004). It is designed for heavy-duty use, serving communities of 300 persons.

The typical feature of this pump is the “Hardwood block” that acts as both, bearing and lever mechanism. The pump is designed that the stand can be directly bolted to the protruding 6” steel casing of the borehole, Ø150 mm NB (Nominal Bore).Three different cylinders are available, the smallest one extend the range to a maximum recommended lift of 80 m. The Bush Pump is not corrosion resistant. It requires special skills for installation as well as for the maintenance; it is not a VLOM pump.

Suitable conditions

The Bush pump can be locally manufactured. Photo: RWSN.

Distribution: More than 30,000 in Zimbabwe.

Ø75 mm cylinder: for depths from 3 - 25 m
Ø63.5 mm cylinder: for depths from 20 - 45 m
Ø50 mm cylinder: for depths from 40 - 80 m
Maximum Stroke: 200 - 250 mm
Approx. discharge
(75 watt input,
63.5 mm cylinder):
at 10 m head: 1.4 m³/hour

at 15 m head: 1.1 m³/hour
at 25 m head: 0.8 m³/hour
at 30 m head: 0.7 m³/hour

Pumping lift: 5 - 80 m
Population served: ~ 300 people
Households: 30 - 50 households
Water consumption: 15 - 20 l/per capita
Type of well: borehole or dug well


Construction, operations and maintenance

Pump stand is made of mild steel painted, handle & riser pipes of galvanized GI pipe, pump rods are of galvanized steel, cylinder of brass, bearing block of hardwood, plunger and foot valve of bronze or brass. This pump is not corrosion resistant and should not be used in areas with aggressive water (pH < 6.5).

The Bush Pump has excellent potential for local manufacturing and is produced by different companies in Zimbabwe.

The installation of the Bush Pump needs well trained area mechanics. Lifting tackle is used for pump installation and maintenance interventions. No special tools are needed.

The pump with the standard configuration has a limited “Community Management Potential”, but it is very reliable and popular with the community. Besides the “Standard” configuration, there exists an “Open Top Cylinder” version (easier to maintain) with different cylinder sizes (Ø50 mm, Ø63.5 mm and Ø75 mm). To make maintenance easy, pump rods with case-hardened hook & eye connectors, are standard (Ø16 mm).

Manuals, videos and links

Acknowledgements