Difference between revisions of "Upflow Anaerobic Sludge Blanket Reactor"
(→References) |
|||
(9 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
− | + | {|style="float: left;" | |
− | {{ | + | |{{Language-box|english_link=Upflow_Anaerobic_Sludge_Blanket_Reactor|french_link=Digesteur_anaérobie_à_flux_ascendant|spanish_link=Reactor_Anaerobico_de_Flujo_Ascendente_con_Manto_de_Lodos|hindi_link=coming soon|malayalam_link=coming soon|tamil_link=coming soon | korean_link=coming soon | chinese_link=Coming soon | indonesian_link=Coming soon | japanese_link=Coming soon}} |
+ | |} | ||
+ | {|width="100%" | ||
+ | |style="width:50%;"|{{santable_new| | ||
sys1=[[Single Pit System |1]]| | sys1=[[Single Pit System |1]]| | ||
− | sys2=[[Blackwater Treatment System with Infiltration| | + | sys2=[[Blackwater Treatment System with Infiltration|6]]| |
− | sys3=[[Blackwater Treatment System with | + | sys3=[[Blackwater Treatment System with Effluent Transport|7]]| |
− | sys4=[[(Semi-) Centralized Treatment System | | + | sys4=[[Blackwater Transport to (Semi-) Centralized Treatment System |8]]| |
− | sys5=[[Sewerage System with Urine Diversion | | + | sys5=[[Sewerage System with Urine Diversion |9]]| |
sys6=| | sys6=| | ||
sys7=| | sys7=| | ||
sys8=| | sys8=| | ||
+ | sys9=| | ||
pic=Upflow_anaerobic_sludge_blanket_reactor1.png| | pic=Upflow_anaerobic_sludge_blanket_reactor1.png| | ||
ApplHousehold=| | ApplHousehold=| | ||
Line 16: | Line 20: | ||
ManShared=| | ManShared=| | ||
ManPublic=XX| | ManPublic=XX| | ||
− | Input1=Blackwater|Input2=Greywater |Input3= | Input4= |Input5=| | + | Input1=Blackwater|Input2=Greywater |Input3=Brownwater | Input4= |Input5=| |
− | Output1= Effluent | Output2= | + | Output1= Effluent | Output2= Sludge | Output3= Biogas | Output4= | Output5= |
− | |||
− | |||
− | |||
}} | }} | ||
+ | |[[Image:Upflow_anaerobic_sludge_blanket_reactor1.png |right|500px]] | ||
+ | |} | ||
+ | <br> | ||
+ | ---- | ||
+ | <br> | ||
− | [[Image:Icon_upflow_anaerobic_sludge_blanket_reactor.png |right| | + | [[Image:Icon_upflow_anaerobic_sludge_blanket_reactor.png |right|80px]] |
− | |||
− | The sludge blanket is | + | '''The upflow anaerobic sludge blanket reactor (UASB) is a single tank process. Wastewater enters the reactor from the bottom, and flows upward. A suspended |
+ | sludge blanket filters and treats the wastewater as the wastewater flows through it.''' | ||
− | + | <br> | |
+ | The sludge blanket is comprised of microbial granules (1 to 3 mm in diameter), i.e., small agglomerations of microorganisms that, because of their weight, resist being washed out in the upflow. The microorganisms in the sludge layer degrade organic compounds. As a result, gases (methane and carbon dioxide) are released. The rising bubbles mix the sludge without the assistance of any mechanical parts. Sloped walls deflect material that reaches the top of the tank downwards. The clarified effluent is extracted from the top of the tank in an area above the sloped walls. | ||
− | + | After several weeks of use, larger granules of sludge form which, in turn, act as filters for smaller particles as the effluent rises through the cushion of sludge. | |
+ | Because of the upflow regime, granule-forming organisms are preferentially accumulated as the others are washed out. | ||
+ | ===Design Considerations=== | ||
+ | Critical elements for the design of UASB reactors are the influent distribution system, the gas-solids separator, and the effluent withdrawal design. The gas that rises to the top is collected in a gas collection dome and can be used as energy (biogas). An upflow velocity of 0.7 to 1 m/h must be maintained to keep the sludge blanket in suspension. Primary settling is usually not required before the UASB. | ||
+ | |||
+ | <br> | ||
{{procontable | pro= | {{procontable | pro= | ||
- High reduction in organics. <br> - Can withstand high organic loading rates (up to 10kg BOD/m3/d) and high hydraulic loading rates. <br> - Low production sludge (and thus, infrequent desludging required). <br> - Biogas can be used for energy (but usually requires scrubbing first). | con= | - High reduction in organics. <br> - Can withstand high organic loading rates (up to 10kg BOD/m3/d) and high hydraulic loading rates. <br> - Low production sludge (and thus, infrequent desludging required). <br> - Biogas can be used for energy (but usually requires scrubbing first). | con= | ||
Line 37: | Line 49: | ||
}} | }} | ||
− | == | + | ===Appropriateness=== |
− | + | A UASB is not appropriate for small or rural communities without a constant water supply or electricity. The technology is relatively simple to design and build, but developing the granulated sludge may take several months. The UASB reactor has the potential to produce higher quality effluent than [[Septic Tank|Septic Tanks]] (S.9), and can do so in a smaller reactor volume. Although it is a well-established process for large-scale industrial wastewater treatment and high organic loading rates up to 10 kg BOD/m3/d, its application to domestic sewage is still relatively new. | |
− | A UASB is not appropriate for small or rural communities without a constant water supply or electricity. | ||
− | + | It is often used for brewery, distillery, food processing and pulp and paper waste since the process typically removes 80 to 90% of COD. Where the influent is low strength or where it contains too many solids, proteins or fats, the reactor may not work properly. Temperature is also a key factor affecting the performance. or fats, the reactor may not work properly. Temperature is also a key factor affecting the performance. | |
− | ==Health Aspects/Acceptance== | + | ===Health Aspects/Acceptance=== |
+ | The operators should take proper health and safety measures while working in the plant, such as adequate protective clothing. Effluent and sludge still pose a health risk and should not be directly handled. | ||
− | UASB is a | + | ===Operation & Maintenance=== |
+ | The UASB is a Centralized Treatment technology that must be operated and maintained by professionals. A skilled operator is required to monitor the reactor and repair parts, e.g., pumps, in case of problems. Desludging is infrequent and only excess sludge is removed every 2 to 3 years. | ||
− | == | + | ===References=== |
+ | * Lettinga, G., Roersma, R. and Grin, P. (1983). Anaerobic Treatment of Raw Domestic Sewage at Ambient Temperatures Using a Granular Bed UASB Reactor. Biotechnology and Bioengineering 25 (7): 1701-1723. (The first paper describing the process) | ||
− | + | * von Sperling, M. and de Lemos Chernicharo, C. A. (2005). [https://www.iwapublishing.com/sites/default/files/ebooks/9781780402734.pdf Biological Wastewater Treatment in Warm Climate Regions, Volume One]. IWA Publishing, London, UK. pp. 741-804. (Detailed design information) | |
− | + | * Tare, V. and Nema, A. (n.d.). [http://unapcaem.org/Activities%20Files/A01/UASB%20Technology%20%E2%80%93%20Expectations%20and%20Reality.pdf UASB Technology – Expectations and Reality]. United Nations Asian and Pacific Centre for Agricultural Engineering and Machinery, Beijing, CN. (Assessment of UASB installations in India) | |
− | |||
− | + | * Tchobanoglous, G., Burton, F. L. and Stensel, H. D. (2004). Wastewater Engineering: Treatment and Reuse, Metcalf & Eddy, 4th Ed. (Internat. Ed.). McGraw-Hill, New York, US. pp. 1005-1016. (Book; Detailed description and design information) | |
− | * | + | * Ulrich, A. (Ed.), Reuter, S. (Ed.), Gutterer, B. (Ed.), Sasse, L., Panzerbieter, T. and Reckerzügel, T. (2009). [https://wedc-knowledge.lboro.ac.uk/resources/books/DEWATS_-_Chapter_01.pdf Decentralised Wastewater Treatment Systems (DEWATS) and Sanitation in Developing Countries. A Practical Guide]. WEDC, Loughborough University, Leicestershire, UK. (Short overview) |
− | * | + | * Vigneswaran, S., Balasuriya, B. L. N. and Viraraghavan, T. (1986). [https://www.ircwash.org/sites/default/files/341.2-86AN-2504.pdf Environmental Sanitation Reviews. Anaerobic Wastewater Treatment – Attached Growth and Sludge Blanket Process]. Environmental Sanitation Information Center, AIT, Bangkok, TH. (Good technical overview – Chapter 5) |
− | + | ===Acknowledgements=== | |
− | + | {{:Acknowledgements Sanitation}} | |
− | |||
− | |||
− | |||
− | |||
− |
Latest revision as of 03:51, 30 October 2020
|
|
The upflow anaerobic sludge blanket reactor (UASB) is a single tank process. Wastewater enters the reactor from the bottom, and flows upward. A suspended sludge blanket filters and treats the wastewater as the wastewater flows through it.
The sludge blanket is comprised of microbial granules (1 to 3 mm in diameter), i.e., small agglomerations of microorganisms that, because of their weight, resist being washed out in the upflow. The microorganisms in the sludge layer degrade organic compounds. As a result, gases (methane and carbon dioxide) are released. The rising bubbles mix the sludge without the assistance of any mechanical parts. Sloped walls deflect material that reaches the top of the tank downwards. The clarified effluent is extracted from the top of the tank in an area above the sloped walls.
After several weeks of use, larger granules of sludge form which, in turn, act as filters for smaller particles as the effluent rises through the cushion of sludge. Because of the upflow regime, granule-forming organisms are preferentially accumulated as the others are washed out.
Contents
Design Considerations
Critical elements for the design of UASB reactors are the influent distribution system, the gas-solids separator, and the effluent withdrawal design. The gas that rises to the top is collected in a gas collection dome and can be used as energy (biogas). An upflow velocity of 0.7 to 1 m/h must be maintained to keep the sludge blanket in suspension. Primary settling is usually not required before the UASB.
Advantages | Disadvantages/limitations |
---|---|
- High reduction in organics. - Can withstand high organic loading rates (up to 10kg BOD/m3/d) and high hydraulic loading rates. - Low production sludge (and thus, infrequent desludging required). - Biogas can be used for energy (but usually requires scrubbing first). |
- Difficult to maintain proper hydraulic conditions (upflow and settling rate must be balanced). - Long start up time. - Treatment may be unstable with variable hydraulic and organic loads. - Constant source of electricity is required. - Not all parts and materials may be available locally. - Requires expert design and construction supervision. |
Appropriateness
A UASB is not appropriate for small or rural communities without a constant water supply or electricity. The technology is relatively simple to design and build, but developing the granulated sludge may take several months. The UASB reactor has the potential to produce higher quality effluent than Septic Tanks (S.9), and can do so in a smaller reactor volume. Although it is a well-established process for large-scale industrial wastewater treatment and high organic loading rates up to 10 kg BOD/m3/d, its application to domestic sewage is still relatively new.
It is often used for brewery, distillery, food processing and pulp and paper waste since the process typically removes 80 to 90% of COD. Where the influent is low strength or where it contains too many solids, proteins or fats, the reactor may not work properly. Temperature is also a key factor affecting the performance. or fats, the reactor may not work properly. Temperature is also a key factor affecting the performance.
Health Aspects/Acceptance
The operators should take proper health and safety measures while working in the plant, such as adequate protective clothing. Effluent and sludge still pose a health risk and should not be directly handled.
Operation & Maintenance
The UASB is a Centralized Treatment technology that must be operated and maintained by professionals. A skilled operator is required to monitor the reactor and repair parts, e.g., pumps, in case of problems. Desludging is infrequent and only excess sludge is removed every 2 to 3 years.
References
- Lettinga, G., Roersma, R. and Grin, P. (1983). Anaerobic Treatment of Raw Domestic Sewage at Ambient Temperatures Using a Granular Bed UASB Reactor. Biotechnology and Bioengineering 25 (7): 1701-1723. (The first paper describing the process)
- von Sperling, M. and de Lemos Chernicharo, C. A. (2005). Biological Wastewater Treatment in Warm Climate Regions, Volume One. IWA Publishing, London, UK. pp. 741-804. (Detailed design information)
- Tare, V. and Nema, A. (n.d.). UASB Technology – Expectations and Reality. United Nations Asian and Pacific Centre for Agricultural Engineering and Machinery, Beijing, CN. (Assessment of UASB installations in India)
- Tchobanoglous, G., Burton, F. L. and Stensel, H. D. (2004). Wastewater Engineering: Treatment and Reuse, Metcalf & Eddy, 4th Ed. (Internat. Ed.). McGraw-Hill, New York, US. pp. 1005-1016. (Book; Detailed description and design information)
- Ulrich, A. (Ed.), Reuter, S. (Ed.), Gutterer, B. (Ed.), Sasse, L., Panzerbieter, T. and Reckerzügel, T. (2009). Decentralised Wastewater Treatment Systems (DEWATS) and Sanitation in Developing Countries. A Practical Guide. WEDC, Loughborough University, Leicestershire, UK. (Short overview)
- Vigneswaran, S., Balasuriya, B. L. N. and Viraraghavan, T. (1986). Environmental Sanitation Reviews. Anaerobic Wastewater Treatment – Attached Growth and Sludge Blanket Process. Environmental Sanitation Information Center, AIT, Bangkok, TH. (Good technical overview – Chapter 5)
Acknowledgements
The material on this page was adapted from:
Elizabeth Tilley, Lukas Ulrich, Christoph Lüthi, Philippe Reymond and Christian Zurbrügg (2014). Compendium of Sanitation Systems and Technologies, published by Sandec, the Department of Water and Sanitation in Developing Countries of Eawag, the Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.
The 2nd edition publication is available in English. French and Spanish are yet to come.