Difference between revisions of "Urine Storage Tank / Container"

From Akvopedia
Jump to: navigation, search
(References)
 
(25 intermediate revisions by 3 users not shown)
Line 1: Line 1:
<!-- table at top of page with logo, picture, Application level, Management level, and input-output tables -->
+
{|style="float: left;"
{{santable|
+
|{{Language-box|english_link=Urine Storage Tank / Container|french_link=Réservoir_de_stockage_d’urine|spanish_link=Tanque/Contenedor_para_Almacenamiento_de_Orina|hindi_link=coming soon|malayalam_link=coming soon|tamil_link=coming soon | korean_link=coming soon | chinese_link=Coming soon | indonesian_link=Coming soon | japanese_link=Coming soon}}
 +
|}
 +
{|width="100%"
 +
|style="width:50%;"|{{santable_new|
 
sys1=[[Waterless System with Urine Diversion|4]]|
 
sys1=[[Waterless System with Urine Diversion|4]]|
sys2=[[Sewerage System with Urine Diversion|8]]|
+
sys2=[[Biogas System|5]]|
sys3=|
+
sys3=[[Sewerage System with Urine Diversion|9]]|
 
sys4=|
 
sys4=|
 
sys5=|
 
sys5=|
Line 9: Line 12:
 
sys7=|
 
sys7=|
 
sys8=|
 
sys8=|
 +
sys9=|
 
pic=Urine_storage_tank-container.png|
 
pic=Urine_storage_tank-container.png|
 
ApplHousehold=XX|
 
ApplHousehold=XX|
Line 18: Line 22:
 
Input1=Urine|Input2=Faeces |Input3=| Input4= |Input5=|
 
Input1=Urine|Input2=Faeces |Input3=| Input4= |Input5=|
 
Output1=Stored urine| Output2=Faeces | Output3= | Output4= | Output5=
 
Output1=Stored urine| Output2=Faeces | Output3= | Output4= | Output5=
|english_link=Storage_tanks
 
|french_link=Réservoir_de_stockage_d’urine
 
 
}}
 
}}
 +
|[[Image:Urine_storage_tank-container.png |right|500px]]
 +
|}
 +
<br>
 +
----
 +
<br>
  
[[Image:Icon_urine_storage_tank_container.png |right|95px]]
+
[[Image:Icon_urine_storage_tank_container.png |right|80px]]
'''When urine or faeces cannot be used immediately or transported using a Conveyance Technology (i.e. Jerrycans or oil drums) it can be stored onsite in containers or tanks. The Storage Tank must then be moved or emptied into another container for transport. '''
+
'''When urine cannot be used immediately or transported using a Conveyance technology (i.e.,[[Jerrycan - tank | Jerrycans]], see C.1), it can be stored onsite in containers or tanks. The storage tank must then be moved or emptied into another container for transport.'''
  
[[Image:Oil_drums_and_containers.PNG|thumb|right|150px|[[Oil drums and containers |Oil drums and containers]], in Uganda(for credits, click the picture)]]
+
[[Image:Oil_drums_and_containers.PNG|thumb|right|200px|[[Oil drums and containers |Oil drums and containers]], in Uganda(for credits, click the picture)]]
  
===Urine===
+
The urine storage tank should be appropriately sized to accommodate the number of users and the time required to sanitize the urine. The storage guidelines for urine correspond to the temperature of storage and the intended crop for which it would be used as fertilizer, but all urine should be stored for at least 1 month before use (see WHO guidelines for specific storage and application guidelines). If a family’s urine is used to fertilize crops for their own household consumption only, it can be used directly without storage.
The Storage Tank should be appropriately sized to accommodate the number of users and the time required to sanitise the urine. Urine collected in small containers (up to 20 litres) can be easily transported and used as fertiliser in the household's own vegetable garden. Larger containers, filled with urine have to be collected by a vehicle and can therefore be transported over longer distances.
 
  
The storage guidelines for urine correspond to the temperature of storage and the intended crop, but all urine should be stored for at least 1 month (see WHO guidelines for specific storage and application guidelines). Smaller volume Storage Tanks can be used and transported to another, centralized Storage Tank at, or close to, the point of use (i.e. the farm).  
+
Smaller volume storage tanks can be used and transported to another centralized storage tank at, or close to, the point of use (i.e., the farm).
  
Mobile Storage Tanks should be plastic or fibreglass, but permanent Storage Tanks can be made of concrete or plastic. Metal should be avoided as it can be easily corroded by the high pH of stored urine.  
+
===Design Considerations===
 +
On average, a person generates about 1.2 L of urine a day; however, this quantity may vary significantly depending on the climate and fluid consumption. Mobile storage tanks should be made of plastic or fibreglass, but permanent ones can be comprised of concrete or plastic. Metal should be avoided as it can easily be corroded by the high pH of
 +
stored urine.
  
With storage time, a layer of organic sludge and precipitated minerals (primarily calcium and magnesium phosphates) will form on the bottom of the tank. Any tank used for urine storage should have an opening large enough so that it can be cleaned and/ or pumped out.  
+
Over time, a layer of organic sludge and precipitated minerals (primarily calcium and magnesium phosphates) will form on the bottom of the tank. Any tank used for urine storage should have an opening large enough so that it can be cleaned and/or pumped out. Neither the storage tank, nor the collection pipes should be ventilated to avoid odorous ammonia emissions, but they both need to be pressure equalized. If the storage tank is directly connected with a pipe to the toilet or urinal, care should be taken to minimize the length of the pipe since precipitates will accumulate.
  
Neither the Storage Tank, nor the collection pipes should be ventilated, but they both need to be pressure equalized. If the Storage Tank is emptied using a vacuum truck, the inflow of air must be maintained at a sufficient rate to ensure that the tank does not implode due to the vacuum.  
+
Pipes should have a steep slope (> 1%), no sharp angles, and large diameters (up to 110 mm for underground pipes). They should be easily accessible in case of blockages. To minimize odours and nitrogen loss, the tank should be filled from the bottom, i.e., the urine should flow down through a pipe and be released near the bottom of the tank. This will prevent the urine from spraying and avoid the backflow of air.
  
If the Storage Tank is connected to the toilet or urinal directly with a pipe, care should be taken to minimize the length of the pipe since precipitates will accumulate. If pipes must be used, they should have a steep slope (greater than 1% slope), no sharp angles, large diameters (up to 110mm for underground pipes) and be easily removable in case of blockages.
 
  
To minimize odours, the tank should be filled from the bottom, i.e. the urine should flow down through a pipe and be released near the bottom of the tank; this will prevent the urine from spraying as well as prevent back-flow.
+
{| border="1" cellpadding="5" cellspacing="0" align="none"
 +
|-
 +
! width="50%" style="background:#efefef;" | Advantages
 +
! style="background:#f0f8ff;" | Disadvantages
 +
|-
 +
| valign="top" |
 +
- Simple and robust technology <br>
 +
- Can be built and repaired with locally available materials <br>
 +
- Low risk of pathogen transmission <br>
 +
- Stored urine can be used as a fertilizer <br>
 +
- Small land area required <br>
 +
- No or low operating costs if self-emptied
 +
| valign="top" |
 +
- Mild to strong odour when opening and emptying tank (depending on storage conditions)<br>
 +
- May require frequent emptying (depending on tank size)
 +
|}
  
===Faeces===
+
<br>
Oil drums, or half drums, can be placed directly beneath a toilet to collect faeces. Ash or other drying material has to be added regularly to prevent smells. Toilet paper can also be collected in the oil drum.  
+
===Appropriateness===  
 +
Urine storage tanks are most appropriate where there is a need for nutrients from fertilizer for agriculture which can be supplied by the stored urine. When there is no such need, the urine can become a source of pollution and a nuisance. Urine storage tanks can be used in virtually every environment; tanks should be well-sealed to prevent
 +
leaks, infiltration and nitrogen loss. Urine storage tanks can be installed indoors, outdoors, above ground and below ground depending on the climate, space available, and soil.
  
{{procontable | pro=
+
===Health Aspects/Acceptance===  
- Can be built and repaired with locally available materials <br>- No electrical energy required <br>- Can be used immediately <br>- Small land area required <br>- Low capital and operating costs| con= - Mild to strong odour when opening and emptying tank (depending on storage conditions)
+
Long-term storage is the best way to sanitize urine without the addition of chemicals or mechanical processes. The risk of disease transmission from stored urine is low. Extended storage with storage times greater than 6 months provides near complete sanitization.
}}
 
 
 
==Adequacy==
 
 
 
Containers are not suitable for the collection of mixed urine and excreta.
 
 
 
Collection of oil drums and containers at community level has to be made functioning beforehand and measures have to be taken to guarantee hygienic safety. Sizes and weights must be manageable.
 
 
 
Long-term storage is the best way to sanitize urine without the addition of chemicals or mechanical processes.  
 
 
 
Urine Storage Tanks can be used in virtually every environment; tanks should be well-sealed to prevent leaks, infiltration and evaporation. Urine Storage Tanks can be installed indoors, outdoors, above ground and below ground depending on the climate, space available, and soil.  
 
  
==Health Aspects / Acceptance==
+
===Operation & Maintenance===  
The risk of disease transmission from stored urine is low. Extended storage with storage times greater than 6 months provides near complete sanitation.  
+
If the storage tank is emptied using a vacuum truck (see C.3), the inflow of air must be maintained at a sufficient rate to ensure that the tank does not implode due to the vacuum. A viscous sludge will accumulate on the bottom of the
 +
storage tank. When the storage tank is emptied, the sludge will usually be emptied along with the urine, but if a tap is used and the tank is never fully emptied, it may require desludging. The desludging period will depend on the composition of the urine and the storage conditions. Mineral and salt build-up in the tank or in connecting pipes can be manually removed (sometimes with difficulty) or dissolved with a strong acid (24% acetic).
  
==Maintenance==
+
=== Manual, videos, and links ===
A viscous sludge will accumulate on the bottom of the Storage Tank. When the Storage Tank is emptied, the sludge will usually be emptied along with the urine, but if a tap is used and the tank is never fully emptied, it may require desludging. The desludging period will depend on the composition of the urine and the storage conditions.
+
* [http://www.who.int/water_sanitation_health/publications/guidelines-on-sanitation-and-health/en/ WHO: Guidelines on sanitation and health - 2018]
  
Mineral and salt build-up in the tank or on connecting pipes can be manually removed (sometimes with difficulty) or can be dissolved with a strong acid (24% acetic).  
+
===References ===
 +
* Kvarnström, E., Emilsson, K., Richert Stintzing, A., Johansson, M., Jönsson, H., af Petersens, E., Schönning, C., Christensen, J., Hellström, D., Qvarnström, L., Ridderstolpe, P. and Drangert, J.-O. (2006). [http://mediamanager.sei.org/documents/Publications/SEI-Report-Kvarnstrom-UrineDiversion-2006-1.pdf Urine Diversion: One Step Towards Sustainable Sanitation]. Report 2006–1, EcoSanRes: Ecosan Publications Series, Stockholm, SE.
  
== Movie ==
+
* von Münch, E. and Winker, M. (2011). [http://www.susana.org/_resources/documents/default/2-875-giz2011-en-technology-review-urine-diversion.pdf Technology Review of Urine Diversion Components. Overview of Urine Diversion Components Such as Waterless Urinals, Urine Diversion Toilets, Urine Storage and Reuse Systems]. Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH, Eschborn, DE.
  
== Manual - How to build ==
+
* WHO (2006). [https://www.who.int/water_sanitation_health/publications/gsuweg4/en/ Guidelines for the Safe Use of Wastewater, Excreta and Greywater. Volume 4: Excreta and Greywater Use in Agriculture]. World Health Organization, Geneva, CH.
  
==Acknowledgements==
+
===Acknowledgements===
 
{{:Acknowledgements Sanitation}}
 
{{:Acknowledgements Sanitation}}
 
==References and external links==
 
 
* GTZ (2007). Technical data sheet, urine diversion: Piping and storage. GTZ, Germany. Available: [http://www.gtz.de www.gtz.de]
 
* Kvarnström, E., et al. (2006). Urine Diversion - One step towards sustainable sanitation. Report 2006-1. Ecosan Res: Ecosan Publication Series, Stockholm. Available: [http://www.ecosanres.org www.ecosanres.org]
 
* WHO (2006). Guidelines for the safe use of wastewater, excreta and greywater- Volume 4: Excreta and greywater use in agriculture. WHO, Geneva. Available: [http://www.who.int www.who.int]
 
* General information about Oil drums and containers [http://www.gtz.de/ecosan www.gtz.de/ecosan ] [http://www.waste.nl www.waste.nl ]
 
* The Philippines [http://www.caps.ph www.caps.ph ]
 
* India [http://www.sulabhinternational.org www.sulabhinternational.org ]
 

Latest revision as of 22:29, 5 September 2020

English Français Español भारत മലയാളം தமிழ் 한국어 中國 Indonesia Japanese
Applicable in systems:
4, 5 , 9
Level of Application
Household XX
Neighbourhood XX
City X

 

Inputs
Urine, Faeces


Level of management
Household XX
Shared XX
Public XX

 

Outputs
Stored urine, Faeces
Urine storage tank-container.png




Icon urine storage tank container.png

When urine cannot be used immediately or transported using a Conveyance technology (i.e., Jerrycans, see C.1), it can be stored onsite in containers or tanks. The storage tank must then be moved or emptied into another container for transport.

Oil drums and containers, in Uganda(for credits, click the picture)

The urine storage tank should be appropriately sized to accommodate the number of users and the time required to sanitize the urine. The storage guidelines for urine correspond to the temperature of storage and the intended crop for which it would be used as fertilizer, but all urine should be stored for at least 1 month before use (see WHO guidelines for specific storage and application guidelines). If a family’s urine is used to fertilize crops for their own household consumption only, it can be used directly without storage.

Smaller volume storage tanks can be used and transported to another centralized storage tank at, or close to, the point of use (i.e., the farm).

Design Considerations

On average, a person generates about 1.2 L of urine a day; however, this quantity may vary significantly depending on the climate and fluid consumption. Mobile storage tanks should be made of plastic or fibreglass, but permanent ones can be comprised of concrete or plastic. Metal should be avoided as it can easily be corroded by the high pH of stored urine.

Over time, a layer of organic sludge and precipitated minerals (primarily calcium and magnesium phosphates) will form on the bottom of the tank. Any tank used for urine storage should have an opening large enough so that it can be cleaned and/or pumped out. Neither the storage tank, nor the collection pipes should be ventilated to avoid odorous ammonia emissions, but they both need to be pressure equalized. If the storage tank is directly connected with a pipe to the toilet or urinal, care should be taken to minimize the length of the pipe since precipitates will accumulate.

Pipes should have a steep slope (> 1%), no sharp angles, and large diameters (up to 110 mm for underground pipes). They should be easily accessible in case of blockages. To minimize odours and nitrogen loss, the tank should be filled from the bottom, i.e., the urine should flow down through a pipe and be released near the bottom of the tank. This will prevent the urine from spraying and avoid the backflow of air.


Advantages Disadvantages

- Simple and robust technology
- Can be built and repaired with locally available materials
- Low risk of pathogen transmission
- Stored urine can be used as a fertilizer
- Small land area required
- No or low operating costs if self-emptied

- Mild to strong odour when opening and emptying tank (depending on storage conditions)
- May require frequent emptying (depending on tank size)


Appropriateness

Urine storage tanks are most appropriate where there is a need for nutrients from fertilizer for agriculture which can be supplied by the stored urine. When there is no such need, the urine can become a source of pollution and a nuisance. Urine storage tanks can be used in virtually every environment; tanks should be well-sealed to prevent leaks, infiltration and nitrogen loss. Urine storage tanks can be installed indoors, outdoors, above ground and below ground depending on the climate, space available, and soil.

Health Aspects/Acceptance

Long-term storage is the best way to sanitize urine without the addition of chemicals or mechanical processes. The risk of disease transmission from stored urine is low. Extended storage with storage times greater than 6 months provides near complete sanitization.

Operation & Maintenance

If the storage tank is emptied using a vacuum truck (see C.3), the inflow of air must be maintained at a sufficient rate to ensure that the tank does not implode due to the vacuum. A viscous sludge will accumulate on the bottom of the storage tank. When the storage tank is emptied, the sludge will usually be emptied along with the urine, but if a tap is used and the tank is never fully emptied, it may require desludging. The desludging period will depend on the composition of the urine and the storage conditions. Mineral and salt build-up in the tank or in connecting pipes can be manually removed (sometimes with difficulty) or dissolved with a strong acid (24% acetic).

Manual, videos, and links

References

  • Kvarnström, E., Emilsson, K., Richert Stintzing, A., Johansson, M., Jönsson, H., af Petersens, E., Schönning, C., Christensen, J., Hellström, D., Qvarnström, L., Ridderstolpe, P. and Drangert, J.-O. (2006). Urine Diversion: One Step Towards Sustainable Sanitation. Report 2006–1, EcoSanRes: Ecosan Publications Series, Stockholm, SE.

Acknowledgements

Eawag compendium cover.png

The material on this page was adapted from:

Elizabeth Tilley, Lukas Ulrich, Christoph Lüthi, Philippe Reymond and Christian Zurbrügg (2014). Compendium of Sanitation Systems and Technologies, published by Sandec, the Department of Water and Sanitation in Developing Countries of Eawag, the Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.

The 2nd edition publication is available in English. French and Spanish are yet to come.