[[Image:Building a horizontal cistern.jpg|thumb|right|200px|Building a horizontal cistern. Photo: from the video: [http://vimeo.com/8452760 How to build a horizontal cistern]]]
[[Image:Building a horizontal cistern.jpg|thumb|right|300px|Building a horizontal cistern]]
+
[[Image:roman cistern.jpg|thumb|right|200px|A Roman cistern back from a long time ago. Used as a water holding "tank". Photo: [http://www.danheller.com/images/Europe/Turkey/Lydea/Slideshow/img3.html DanHeller.com].]]
 
+
[[Image:horizontal cistern lid.jpg|thumb|right|200px|Building the lid for a horizontal cistern. Photo: from the video: [http://vimeo.com/8452760 How to build a horizontal cistern]]]
 +
[[Image:horizontal cistern mud.jpg|thumb|right|200px|Adding a smooth mud wall to the inside of a horizontal cistern. Photo: from the video: [http://vimeo.com/8452760 How to build a horizontal cistern]]]
 +
__NOTOC__ <small-title />
 
The horizontal cistern is a variation of the regular EMAS vertical design, more suitable for ground where it is not possible to dig deep.  
 
The horizontal cistern is a variation of the regular EMAS vertical design, more suitable for ground where it is not possible to dig deep.  
  
Line 10: Line 12:
 
EMAS is the acronym for Escuela Móvil de Agua y Saneamiento (Mobile School for Water and Sanitation), in Bolivia, whose director, Wolfgang Eloy Buchner, developed the EMAS pump in the 1990s.  EMAS is not only the name of the mobile school for water and sanitation, but also a whole technical and social concept of water and sanitation which includes rain water harvesting, solar water heaters, windpower, hydraulic rams, water treatment, small tanks and sinks, a variety of hand and foot pumps, and ferrocement tanks. The aim of the technologies and systems is to achieve the necessary supply of drinkable water, and water for micro irrigation in rural and sub urban areas.
 
EMAS is the acronym for Escuela Móvil de Agua y Saneamiento (Mobile School for Water and Sanitation), in Bolivia, whose director, Wolfgang Eloy Buchner, developed the EMAS pump in the 1990s.  EMAS is not only the name of the mobile school for water and sanitation, but also a whole technical and social concept of water and sanitation which includes rain water harvesting, solar water heaters, windpower, hydraulic rams, water treatment, small tanks and sinks, a variety of hand and foot pumps, and ferrocement tanks. The aim of the technologies and systems is to achieve the necessary supply of drinkable water, and water for micro irrigation in rural and sub urban areas.
  
==Suitable Conditions==  
+
===Suitable Conditions===  
{{Climate_change
+
The Horizontal cistern is suitable in areas with rocky ground, where it is not possible to dig deep enough for a vertical cistern.  
|heading1=Drought effects on cement
+
 
|text1='''Effects of drought''': Badly made concrete or cracked linings (e.g. in tanks, dams, waterways, wells, and other structures). <br>'''Underlying causes of effects''': Less water used for curing; Impure water used for mixing. <br>'''To increase resiliency of WASH system''': Ensure adequate mixing, ratios, purity of ingredients; Minimize water content in mixture; Ensure adequate curing.
 
}}
 
  
The Horizontal cistern is suitable in areas with rocky ground, where it is not possible to dig deep enough for a vertical cistern.
+
{| border="1" cellpadding="5" cellspacing="0" align="center"
{{procontable | pro=
+
|-
- A water truck can simply let water fall into the tank by gravity – no pump required <br>
+
! width="50%" style="background:#efefef;" | Advantages
 +
! style="background:#f0f8ff;" | Disadvantages
 +
|-
 +
| valign="top" | - A water truck can simply let water fall into the tank by gravity – no pump required <br>
 
- Water can be directly pumped into a household storage tank with an EMAS pump <br>
 
- Water can be directly pumped into a household storage tank with an EMAS pump <br>
- 7000l tank with pump costs 70$ in Bolivia <br>
+
- 7000L tank with pump costs US$ 70 in Bolivia <br>
 
- Tank occupies little space – is less noticeable <br>
 
- Tank occupies little space – is less noticeable <br>
- Easy to filter roofwater before it entering the tank <br>
+
- Easy to filter roofwater before it enters the tank <br>
- Temperature underground is more constant – cracks are likely <br>
+
- Temperature underground is more constant <br>
 
- Does not require ground to be firm, like the vertical cistern. <br>
 
- Does not require ground to be firm, like the vertical cistern. <br>
| con=  
+
| valign="top" | - More complicated to build than a vertical cistern <br>
- More complicated to build than a vertical cistern <br>
+
- If the cistern is an open underground tank, contamination (livestock, rainwater runoff carrying pesticides) is more probable, therefore a lid is recommended.<br>
}}
+
- Cracks are likely and harder to detect.
 +
|}
 +
 
 +
===Resilience to changes in the environment===
 +
====Drought====
 +
 
 +
'''Effects of drought''': Badly made concrete and cracked linings (e.g. in tanks, dams, waterways, wells, and other structures). <br>
 +
'''Underlying causes of effects''': Less water used for curing; Impure water used for mixing. <br>
 +
'''To increase resiliency of WASH system''': Ensure adequate mixing, ratios, purity of ingredients; Minimize water content in mixture; Ensure adequate curing.
 +
 
 +
For more information on drought: [[Resilient WASH systems in drought-prone areas]]
  
==Construction, operations and maintenance==   
+
===Construction, operations and maintenance===   
 
It is operated in the same way as a vertical cistern.
 
It is operated in the same way as a vertical cistern.
  
 
The horizontal cistern is around 1m x 3m large, and can be up to 2.5m deep.  
 
The horizontal cistern is around 1m x 3m large, and can be up to 2.5m deep.  
It consists of two sections, one which is slightly deeper, and round, similar to the vertical cistern. This is done so there is room for a pump. The other is the vault, which is long, and less deep.  
+
It consists of two sections, one which is slightly deeper and round, similar to the vertical cistern. This is done so there is room for a pump. The other is the vault, which is long and less deep.  
 
   
 
   
First a hole is dug for the cistern. It should be less deep in the area where the vault is, and deepen on one end, where the pump will be. Then the arch shaped cover for the vault is manufactured using sticks and mud as a mold. The cover is made of 2 layers of cement, with stones in between. The cement is left to dry for 4 days. The walls of the cistern are then built, with layers of mud and cement of different thicknesses. Then the walls, curbstone, cover and pump are installed in the other section, in a similar way to how it is done with the vertical cistern.  
+
First a hole is dug for the cistern. It should be less deep in the area where the vault is and deeper on one end where the pump will be. Then the arch shaped cover for the vault is manufactured using sticks and mud as a mold. The cover is made of 2 layers of cement, with stones in between. The cement is left to dry for 4 days. The walls of the cistern are then built, with layers of mud and cement of different thicknesses. Then the walls, curbstone, cover and pump are installed in the other section, in a similar way to how it is done with the vertical cistern.
 
 
==Costs==
 
  
==Field Experiences==  
+
===Costs===
 +
Costs can be divided as such: 1/3 = cost of materials; 1/3 = cost of transport, labour, etc.; and 1/3 = cost to cover failures, or replacements.
  
==Reference manuals, videos, and links==
+
===Manuals, videos, and links===
* How to build a horizontal cistern - http://vimeo.com/8452760
+
* VIDEO: [http://vimeo.com/8452760 How to build a horizontal cistern] The horizontal cistern instructions start at 12:36.
 
* [http://rainwater-toolkit.net/fileadmin/rwh-material/haury/00_HAUR.pdf The Plate Cistern Project Management and Construction Manual.]
 
* [http://rainwater-toolkit.net/fileadmin/rwh-material/haury/00_HAUR.pdf The Plate Cistern Project Management and Construction Manual.]
 +
* [http://www.lenntech.com/small-community-water-supplies.htm#ixzz2TsbJyNk6 Water supply in small communities], by Lara Fabrizi. Includes how best to manage the planning, construction, and operation and maintenance of water projects or tanks.
  
==Acknowledgements==
+
===Acknowledgements===
 +
* Buchner, Wolfgang.  [http://www.emas-international.de/fileadmin/pics/virtueller_lehrgang/lehrbuecher/water_for_everybody_6_2012.pdf Water for Everybody: A Selection of Appropriate Technologies to be used for Drinkable Water EMAS]. EMAS Water and Basic Sanitation Mobile School. 5th edition, 2006.

Latest revision as of 07:25, 2 October 2013

Building a horizontal cistern. Photo: from the video: How to build a horizontal cistern
A Roman cistern back from a long time ago. Used as a water holding "tank". Photo: DanHeller.com.
Building the lid for a horizontal cistern. Photo: from the video: How to build a horizontal cistern
Adding a smooth mud wall to the inside of a horizontal cistern. Photo: from the video: How to build a horizontal cistern

The horizontal cistern is a variation of the regular EMAS vertical design, more suitable for ground where it is not possible to dig deep.

EMAS Cisterns are underground tanks coated with a thin layer of cement mortar and made waterproof with a pure cement whitewash. It is common for 2-3 cisterns to be constructed per household, particularly when rainwater is the main water source, for a total of 4000-8000 litres of space. An EMAS pump can be installed as well to pump water to local faucets in the house.

The cistern can also be used as a reserve water supply, where the water supply from wells is irregular or only available during the rainy season. This is also useful if the regular water supply is suitable for washing, etc. but too salty or polluted for drinking. It can also be used to store treated sewage water until it can be used for irrigation. It can further be used as a treatment tank for example for flocculation of turbid water.

EMAS is the acronym for Escuela Móvil de Agua y Saneamiento (Mobile School for Water and Sanitation), in Bolivia, whose director, Wolfgang Eloy Buchner, developed the EMAS pump in the 1990s. EMAS is not only the name of the mobile school for water and sanitation, but also a whole technical and social concept of water and sanitation which includes rain water harvesting, solar water heaters, windpower, hydraulic rams, water treatment, small tanks and sinks, a variety of hand and foot pumps, and ferrocement tanks. The aim of the technologies and systems is to achieve the necessary supply of drinkable water, and water for micro irrigation in rural and sub urban areas.

Suitable Conditions

The Horizontal cistern is suitable in areas with rocky ground, where it is not possible to dig deep enough for a vertical cistern.


Advantages Disadvantages
- A water truck can simply let water fall into the tank by gravity – no pump required

- Water can be directly pumped into a household storage tank with an EMAS pump
- 7000L tank with pump costs US$ 70 in Bolivia
- Tank occupies little space – is less noticeable
- Easy to filter roofwater before it enters the tank
- Temperature underground is more constant
- Does not require ground to be firm, like the vertical cistern.

- More complicated to build than a vertical cistern

- If the cistern is an open underground tank, contamination (livestock, rainwater runoff carrying pesticides) is more probable, therefore a lid is recommended.
- Cracks are likely and harder to detect.

Resilience to changes in the environment

Drought

Effects of drought: Badly made concrete and cracked linings (e.g. in tanks, dams, waterways, wells, and other structures).
Underlying causes of effects: Less water used for curing; Impure water used for mixing.
To increase resiliency of WASH system: Ensure adequate mixing, ratios, purity of ingredients; Minimize water content in mixture; Ensure adequate curing.

For more information on drought: Resilient WASH systems in drought-prone areas

Construction, operations and maintenance

It is operated in the same way as a vertical cistern.

The horizontal cistern is around 1m x 3m large, and can be up to 2.5m deep. It consists of two sections, one which is slightly deeper and round, similar to the vertical cistern. This is done so there is room for a pump. The other is the vault, which is long and less deep.

First a hole is dug for the cistern. It should be less deep in the area where the vault is and deeper on one end where the pump will be. Then the arch shaped cover for the vault is manufactured using sticks and mud as a mold. The cover is made of 2 layers of cement, with stones in between. The cement is left to dry for 4 days. The walls of the cistern are then built, with layers of mud and cement of different thicknesses. Then the walls, curbstone, cover and pump are installed in the other section, in a similar way to how it is done with the vertical cistern.

Costs

Costs can be divided as such: 1/3 = cost of materials; 1/3 = cost of transport, labour, etc.; and 1/3 = cost to cover failures, or replacements.

Manuals, videos, and links