Difference between revisions of "Solids-free Sewer"

From Akvopedia
Jump to: navigation, search
(References)
 
(18 intermediate revisions by 3 users not shown)
Line 1: Line 1:
<!-- table at top of page with logo, picture, Application level, Management level, and input-output tables -->
+
{|style="float: left;"
{{santable|
+
|{{Language-box|english_link=Solids-free_Sewer|french_link=Réseau_d’égout_simplifié_sans_matières_solides|spanish_link=Alcantarillados_Libres_de_Solidos|hindi_link=coming soon|malayalam_link=coming soon|tamil_link=coming soon | korean_link=coming soon | chinese_link=Coming soon | indonesian_link=Coming soon | japanese_link=Coming soon}}
sys1=[[Blackwater Treatment System with Sewerage|6]]|
+
|}
 +
{|width="100%"
 +
|style="width:50%;"|{{santable_new|
 +
sys1=[[Blackwater Treatment System with Effluent Transport|7]]|
 
sys2=|
 
sys2=|
 
sys3=|
 
sys3=|
Line 9: Line 12:
 
sys7=|
 
sys7=|
 
sys8=|
 
sys8=|
 +
sys9=|
 
pic=Solids_free_sewer.png|
 
pic=Solids_free_sewer.png|
 
ApplHousehold=|
 
ApplHousehold=|
 
ApplNeighbourhood=XX|
 
ApplNeighbourhood=XX|
 
ApplCity=X|
 
ApplCity=X|
ManHousehold=XX|
+
ManHousehold=X|
 
ManShared=XX|
 
ManShared=XX|
 
ManPublic=XX|
 
ManPublic=XX|
Line 19: Line 23:
 
Output1= Effluent| Output2=| Output3= | Output4= | Output5=
 
Output1= Effluent| Output2=| Output3= | Output4= | Output5=
 
}}
 
}}
 +
|[[Image:Solids_free_sewer.png |right|500px]]
 +
|}
 +
<br>
 +
----
 +
<br>
  
 +
[[Image:Icon_solids_free_sewer.png |right|80px]]
  
'''A Solids-Free Sewer is a network of small diameter pipes that transports solids-free or pre-treated wastewater (such as [[Septic Tank]] or settling tank effluent) to a treatment facility for further treatment or to a discharge point. Solids-Free Sewers are also referred to as settled, small-bore, small-diameter, variable-grade gravity, or septic tank effluent gravity sewers.'''
+
'''A solids-free sewer is a network of small-diameter pipes that transports pre-treated and solids-free wastewater (such as Septic Tank effluent). It can be installed at a shallow depth and does not require a minimum wastewater flow or slope to function.'''
  
A precondition for Solids-Free Sewer networks is efficient pre-treatment at the household level. The interceptor, septic or settling tank removes settleable particles that could clog small pipes. A grease trap should also be added. Because there is little risk of clogging, the sewers do not have to be self-cleaning (i.e. no minimum flow velocity) and can therefore be laid at shallow depths, can have fewer inspection points (manholes), can follow the topography more closely and have inflective gradients (i.e. negative slope). When the sewer roughly follows the ground contours, the flow in the sewer is allowed to vary between open channel flow and pressure (full-bore) flow. However, care should be taken with negative slopes as they may lead to surging above the ground level during peak flows. Inspection points should be provided at major connection points or when the size of the pipe changes.
+
<br>
 +
Solids-free sewers are also referred to as settled, smallbore, variable-grade gravity, or septic tank effluent gravity sewers. A precondition for solids-free sewers is efficient primary treatment at the household level. An interceptor, typically a single-chamber [[Septic Tank]] (S.9), captures settleable particles that could clog small pipes. The solids interceptor also functions to attenuate peak discharges. Because there is little risk of depositions and clogging, solids-free sewers do not have to be self-cleansing, i.e., no minimum flow velocity or tractive tension is needed. They require few inspection points, can have inflective gradients (i.e., negative slopes) and follow the topography. When the sewer roughly follows the ground contours, the flow is allowed to vary between open channel and pressure (full-bore) flow.
  
Despite the possibility that some portions of the pipe can rise higher when going downstream, for the total pipe the downstream end of the sewer must be lower than the upstream end. When choosing a pipe diameter (at least 75mm), the depth of water in the pipe during peak flow within each section must be less than the diameter of the pipe. In sections where there is pressure flow, the invert of any interceptor tank outlet must higher than the hydraulic head within the sewer just prior to the point of connection otherwise the liquid will backflow into the tank. If this condition is not met, then either select the next larger pipe diameter for the sewer or increase the depth at which the sewer is laid.
+
===Design Considerations===
 +
If the interceptors are correctly designed and operated, this type of sewer does not require self-cleansing velocities or minimum slopes. Even inflective gradients are possible, as long as the downstream end of the sewer is lower than the
 +
upstream end. In sections where there is pressure flow, the water level in any interceptor tank must be higher than the hydraulic head within the sewer, otherwise the liquid will flow back into the tank. At high points in sections with pressure flow, the pipes must be ventilated.  
  
{{procontable | pro=
+
Solids-free sewers do not have to be installed on a uniform gradient with a straight alignment between inspection points. The alignment may curve to avoid obstacles, allowing for greater construction tolerance. A minimum diameter of 75 mm is required to facilitate cleaning. Expensive manholes are not needed because access for mechanical cleaning equipment is not necessary. Cleanouts or flushing points are sufficient and are installed at upstream ends, high points, intersections, or major changes in direction or pipe size. Compared to manholes, cleanouts can be more tightly sealed to prevent stormwater from entering.
- Greywater can be managed at the same time. <br> - Can be built and repaired with locally available materials. <br> - Construction can provide short-term employment to local labourers. <br> - Capital costs are less than [[Conventional Gravity Sewer|Conventional Gravity Sewers]]; low operating costs. <br> - Can be extended as a community changes and grows. | con=
 
- Requires expert design and construction supervision. <br> - Requires repairs and removals of blockages more frequently than a Conventional Gravity Sewer. <br> - Requires education and acceptance to be used correctly. <br> - Effluent and sludge (from interceptors) requires secondary treatment and/or appropriate discharge.<br>-High water consumption for excreta removal.  
 
}}
 
  
 +
Stormwater must be excluded as it could exceed pipe capacity and lead to blockages due to grit depositions. Ideally, there should not be any storm- and groundwater in the sewers, but, in practice, some imperfectly sealed pipe joints must be expected. Estimates of groundwater infiltration and stormwater inflow must, therefore, be made when designing the system. The use of PVC pipes can minimize the risk of leakages.
  
==Adequacy==
+
<br>
 
+
{{procontable
Solids-Free Sewers are appropriate for both full and partially filled flows. Although a constant supply of water is required, less water is needed compared to the Simple Sewer because self-cleansing velocities are not required.
+
| pro=
 
+
- Does not require a minimum gradient or flow velocity <br>
[[Septic Tank|Septic Tanks]] and Solids-Free Sewers can be built for new areas, or a Solids-Free Sewer can be connected to an existing primary treatment technology where local infiltration is inappropriate. A Solids-Free Sewer can be built for 20% to 50% less than [[Conventional Gravity Sewer|Conventional Gravity Sewerage]].
+
- Can be used where water supply is limited <br>
 
+
- Lower capital costs than conventional gravity sewers; low operating costs <br>
This technology must be connected to an appropriate [[(Semi-) Centralized Treatment System|(Semi-) Centralized Treatment technology]] that can receive the wastewater. It is appropriate for densely populated areas where there is no space for a [[Soak Pit]] or [[Leach Field]]. This type of sewer is best suited to urban and less appropriate in low-density or rural areas.
+
- Can be extended as a community grows <br>
 
+
- Greywater can be managed concurrently
==Health Aspects/Acceptance==
+
| con=
 
+
- Space for interceptors is required <br>
This technology requires regular maintenance on the part of the users and is therefore, not as passive as [[Conventional Gravity Sewer|Conventional Gravity Sewers]]. Users must assume some level of responsibility for the technology and accept that some potentially unpleasant maintenance may be required. Also, users should be aware that, because the system is community based, they may have to work with and/or coordinate maintenance activities with other users. The system will provide a high level of service and may offer a significant improvement to non-functioning [[Leach Field|Leach Fields]].
+
- Interceptors require regular desludging to prevent clogging <br>
 
+
- Requires training and acceptance to be used correctly <br>
==Upgrading==
+
- Requires repairs and removals of blockages more frequently than a conventional gravity sewer <br>
 
+
- Requires expert design and construction <br>
Solids-Free Sewers are good upgrading options for [[Leach Field|Leach Fields]] that have become clogged and/or saturated with time as well as for rapidly growing areas that would not accommodate more [[Septic Tank|Septic Tanks]] with Leach Fields.
+
- Leakages pose a risk of wastewater exfiltration and groundwater infiltration and are difficult to identify
 +
}}
  
==Maintenance==
+
===Appropriateness===
 +
This type of sewer is best suited to medium-density (peri-)urban areas and less appropriate in low-density or rural settings. It is most appropriate where there is no space for a [[Leach Field]] (D.8), or where effluents cannot otherwise be disposed of onsite (e.g., due to low infiltration capacity or high groundwater). It is also suitable where there is undulating terrain or rocky soil. A solids-free sewer can be connected to existing Septic Tanks where infiltration is no longer appropriate (e.g., due to increased housing density and/or water use).
  
The septic/interceptor tank must be regularly maintained and desludged to insure optimal performance of the Solids-Free Sewer network. If the pre-treatment is efficient, the risk of clogging in the pipes is low, but some maintenance will be required periodically. The sewers should be flushed once a year as part of the regular maintenance regardless of their performance.
+
As opposed to a [[Simplified Sewer]] (C.4) a solids-free sewer can also be used where domestic water consumption
 +
is limited. This technology is a flexible option that can be easily extended as the population grows. Because of shallow
 +
excavations and the use of fewer materials, it can be built at considerably lower cost than a [[Conventional Gravity Sewer | Conventional Sewer]] (C.6).
  
 +
===Health Aspects/Acceptance===
 +
If well constructed and maintained, sewers are a safe and hygienic means of transporting wastewater. Users must be well trained regarding the health risks associated with removing blockages and maintaining interceptor tanks.
  
 +
===Operation & Maintenance===
 +
Trained and responsible users are essential to avoid clogging by trash and other solids. Regular desludging of the Septic Tanks is critical to ensure optimal performance of the sewer. Periodic flushing of the pipes is recommended to insure against blockages. Special precautions should be taken to prevent illegal connections, since it is likely that interceptors would not be installed and solids would enter the system. The sewerage authority, a private contractor or users committee should be responsible for the management of the system, particularly, to ensure that the interceptors
 +
are regularly de-sludged and to prevent illegal connections.
  
==References==
+
===Upgrading===
 +
Solids-Free Sewers are good upgrading options for Leach Fields that have become clogged and/or saturated with time as well as for rapidly growing areas that would not accommodate more Septic Tanks with Leach Fields.
  
* Elizabeth Tilley et.al (2008). [http://www.eawag.ch/organisation/abteilungen/sandec/publikationen/publications_sesp/downloads_sesp/compendium_high.pdf Compendium of Sanitation Systems and Technologies] ([http://www.eawag.ch/organisation/abteilungen/sandec/publikationen/publications_sesp/downloads_sesp/compendium_low.pdf low res version]). Department of Water and Sanitation in Development Countries ([http://www.sandec.ch/ Sandec]) at the Swiss Federal Institute of Aquatic Science and Technology (Eawag). (Provides a full overview of sanitation systems.)
+
===References===
 +
* Azevedo Netto, J. and Reid, R. (1992). [https://www.ircwash.org/sites/default/files/332-92IN-9897.pdf Innovative and Low- Cost Technologies Utilized in Sewerage]. Technical Series No. 29, Environmental Health Program, Pan American Health Organization, Washington, D.C., US. (A short summary and component diagrams – Chapter 5)
  
* Azevedo Netto, MM. and Reid, R. (1992). Innovative and Low Cost Technologies Utilized in Sewerage. Environmental Health Program, Technical Series No. 29. Pan American Health Organization, Washington DC. (A Short summary and component diagrams-Chapter 5.)
+
* Crites, R. and Tchobanoglous, G. (1998). Small and Decentralized Wastewater Management Systems. WCB/McGraw- Hill, New York, US. pp. 355-364. (Book; A short summary of design and construction considerations)
  
* Crites, R. and Tchobanoglous, G. (1998). Small and Decentralized Wastewater Management Systems. WCB and McGraw-Hill, New York, USA. pp 355–364. (A short summary of design and construction considerations.)
+
* Mara, D. D. (1996a). [https://www.susana.org/en/knowledge-hub/resources-and-publications/library/details/2972 Low-Cost Sewerage]. Wiley, Chichester, UK. (Assessment of different low-cost systems and case studies)
  
* Mara, DD. (1996). Low-Cost Sewerage. Wiley, Chicheser, UK. (Assessment of different low-cost systems and case studies.)
+
* Mara, D. D. (1996b). Low-Cost Urban Sanitation. Wiley, Chichester, UK. pp. 93-108. (Book; Comprehensive summary including design examples)
  
* Mara, DD. (1996). Low-Cost Urban Sanitation. Wiley, Chichester, UK. pp 93–108. (Comprehensive summary including design examples.)
+
* Otis, R. J. and Mara, D. D. (1985). [https://www.ircwash.org/resources/design-small-bore-sewer-systems The Design of Small Bore Sewer Systems]. UNDP Interregional Project INT/81/047, The World Bank and UNDP, Washington, D.C., US. (Comprehensive summary of design, installation and maintenance)
  
* Otis, RJ. and Mara, DD. (1985). The Design of Small Bore Sewer Systems (UNDP Interreg. Project INT/81/047). TAG Technical Note No.14. United Nations Development Programme + World Bank, Washington. Available: www.wds.worldbank.org (Comprehensive summary of design, installation and maintenance.)
+
===Acknowledgements===
 +
{{:Acknowledgements Sanitation}}

Latest revision as of 19:27, 3 October 2020

English Français Español भारत മലയാളം தமிழ் 한국어 中國 Indonesia Japanese
Applicable in systems:
7
Level of Application
Household
Neighbourhood XX
City X

 

Inputs
Effluent


Level of management
Household X
Shared XX
Public XX

 

Outputs
Effluent
Solids free sewer.png




Icon solids free sewer.png

A solids-free sewer is a network of small-diameter pipes that transports pre-treated and solids-free wastewater (such as Septic Tank effluent). It can be installed at a shallow depth and does not require a minimum wastewater flow or slope to function.


Solids-free sewers are also referred to as settled, smallbore, variable-grade gravity, or septic tank effluent gravity sewers. A precondition for solids-free sewers is efficient primary treatment at the household level. An interceptor, typically a single-chamber Septic Tank (S.9), captures settleable particles that could clog small pipes. The solids interceptor also functions to attenuate peak discharges. Because there is little risk of depositions and clogging, solids-free sewers do not have to be self-cleansing, i.e., no minimum flow velocity or tractive tension is needed. They require few inspection points, can have inflective gradients (i.e., negative slopes) and follow the topography. When the sewer roughly follows the ground contours, the flow is allowed to vary between open channel and pressure (full-bore) flow.

Design Considerations

If the interceptors are correctly designed and operated, this type of sewer does not require self-cleansing velocities or minimum slopes. Even inflective gradients are possible, as long as the downstream end of the sewer is lower than the upstream end. In sections where there is pressure flow, the water level in any interceptor tank must be higher than the hydraulic head within the sewer, otherwise the liquid will flow back into the tank. At high points in sections with pressure flow, the pipes must be ventilated.

Solids-free sewers do not have to be installed on a uniform gradient with a straight alignment between inspection points. The alignment may curve to avoid obstacles, allowing for greater construction tolerance. A minimum diameter of 75 mm is required to facilitate cleaning. Expensive manholes are not needed because access for mechanical cleaning equipment is not necessary. Cleanouts or flushing points are sufficient and are installed at upstream ends, high points, intersections, or major changes in direction or pipe size. Compared to manholes, cleanouts can be more tightly sealed to prevent stormwater from entering.

Stormwater must be excluded as it could exceed pipe capacity and lead to blockages due to grit depositions. Ideally, there should not be any storm- and groundwater in the sewers, but, in practice, some imperfectly sealed pipe joints must be expected. Estimates of groundwater infiltration and stormwater inflow must, therefore, be made when designing the system. The use of PVC pipes can minimize the risk of leakages.


Advantages Disadvantages/limitations
- Does not require a minimum gradient or flow velocity

- Can be used where water supply is limited
- Lower capital costs than conventional gravity sewers; low operating costs
- Can be extended as a community grows
- Greywater can be managed concurrently

- Space for interceptors is required

- Interceptors require regular desludging to prevent clogging
- Requires training and acceptance to be used correctly
- Requires repairs and removals of blockages more frequently than a conventional gravity sewer
- Requires expert design and construction
- Leakages pose a risk of wastewater exfiltration and groundwater infiltration and are difficult to identify


Appropriateness

This type of sewer is best suited to medium-density (peri-)urban areas and less appropriate in low-density or rural settings. It is most appropriate where there is no space for a Leach Field (D.8), or where effluents cannot otherwise be disposed of onsite (e.g., due to low infiltration capacity or high groundwater). It is also suitable where there is undulating terrain or rocky soil. A solids-free sewer can be connected to existing Septic Tanks where infiltration is no longer appropriate (e.g., due to increased housing density and/or water use).

As opposed to a Simplified Sewer (C.4) a solids-free sewer can also be used where domestic water consumption is limited. This technology is a flexible option that can be easily extended as the population grows. Because of shallow excavations and the use of fewer materials, it can be built at considerably lower cost than a Conventional Sewer (C.6).

Health Aspects/Acceptance

If well constructed and maintained, sewers are a safe and hygienic means of transporting wastewater. Users must be well trained regarding the health risks associated with removing blockages and maintaining interceptor tanks.

Operation & Maintenance

Trained and responsible users are essential to avoid clogging by trash and other solids. Regular desludging of the Septic Tanks is critical to ensure optimal performance of the sewer. Periodic flushing of the pipes is recommended to insure against blockages. Special precautions should be taken to prevent illegal connections, since it is likely that interceptors would not be installed and solids would enter the system. The sewerage authority, a private contractor or users committee should be responsible for the management of the system, particularly, to ensure that the interceptors are regularly de-sludged and to prevent illegal connections.

Upgrading

Solids-Free Sewers are good upgrading options for Leach Fields that have become clogged and/or saturated with time as well as for rapidly growing areas that would not accommodate more Septic Tanks with Leach Fields.

References

  • Crites, R. and Tchobanoglous, G. (1998). Small and Decentralized Wastewater Management Systems. WCB/McGraw- Hill, New York, US. pp. 355-364. (Book; A short summary of design and construction considerations)
  • Mara, D. D. (1996a). Low-Cost Sewerage. Wiley, Chichester, UK. (Assessment of different low-cost systems and case studies)
  • Mara, D. D. (1996b). Low-Cost Urban Sanitation. Wiley, Chichester, UK. pp. 93-108. (Book; Comprehensive summary including design examples)
  • Otis, R. J. and Mara, D. D. (1985). The Design of Small Bore Sewer Systems. UNDP Interregional Project INT/81/047, The World Bank and UNDP, Washington, D.C., US. (Comprehensive summary of design, installation and maintenance)

Acknowledgements

Eawag compendium cover.png

The material on this page was adapted from:

Elizabeth Tilley, Lukas Ulrich, Christoph Lüthi, Philippe Reymond and Christian Zurbrügg (2014). Compendium of Sanitation Systems and Technologies, published by Sandec, the Department of Water and Sanitation in Developing Countries of Eawag, the Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.

The 2nd edition publication is available in English. French and Spanish are yet to come.