Construction, operations and maintenance
# Cover in mortar or cement to waterproof it.
# About 10cm above the ground, another outlet pipe is set, if the cistern becomes too full.
# Cover with a net to prevent insects from entering the tank.
# Cover the walls of the cistern in mud cakes, and 2 layers of cement white wash. The walls should not be too thick or they will crack.
# Build an arch-shaped cover by lying cement on a mold of mud hill covered in plastic. The thickness of the cover depends on the diameter. A 1m wide cover should be about 5cm thick.
# Install the EMAS pump. Its pipe is set in a larger stiff guide pipe, which reaches down to the bottom of the cistern and is fixed in place using cement.
# Cover the guide pipe with a waterproof stopper. Use a knife to perforate this with a small hole for water.
# Cover with a net to prevent insects from entering the tank.
====Maintenance====
Akvopedia-spade, akvouser, bureaucrat, emailconfirmed, staff, susana-working-group-1, susana-working-group-10, susana-working-group-11, susana-working-group-12, susana-working-group-2, susana-working-group-3, susana-working-group-4, susana-working-group-5, susana-working-group-6, susana-working-group-7, susana-working-group-8, susana-working-group-9, susana-working-group-susana-member, administrator, widget editor