A precondition for Solids-Free Sewer networks is efficient pre-treatment at the household level. The interceptor, septic or settling tank removes settleable particles that could clog small pipes. A grease trap should also be added. Because there is little risk of clogging, the sewers do not have to be self-cleaning (i.e. no minimum flow velocity) and can therefore be laid at shallow depths, can have fewer inspection points (manholes), can follow the topography more closely and have inflective gradients (i.e. negative slope). When the sewer roughly follows the ground contours, the flow in the sewer is allowed to vary between open channel flow and pressure (full-bore) flow. However, care should be taken with negative slopes as they may lead to surging above the ground level during peak flows. Inspection points should be provided at major connection points or when the size of the pipe changes.
The Despite the possibility that some portions of the pipe can rise higher when going downstream, for the total pipe the downstream end of the sewer must be lower than the upstream end. When choosing a pipe diameter (at least 75mm), the depth of water in the pipe during peak flow within each section must be less than the diameter of the pipe. In sections where there is pressure flow, the invert of any interceptor tank outlet must higher than the hydraulic head within the sewer just prior to the point of connection otherwise the liquid will backflow into the tank. If this condition is not met, then either select the next larger pipe diameter for the sewer or increase the depth at which the sewer is laid.
{{procontable | pro=
- Greywater can be managed at the same time. <br> - Can be built and repaired with locally available materials. <br> - Construction can provide short-term employment to local labourers. <br> - Capital costs are less than [[Conventional Gravity Sewer|Conventional Gravity Sewers]]; low operating costs. <br> - Can be extended as a community changes and grows. | con=
- Requires expert design and construction supervision. <br> - Requires repairs and removals of blockages more frequently than a Conventional Gravity Sewer. <br> - Requires education and acceptance to be used correctly. <br> - Effluent and sludge (from interceptors) requires secondary treatment and/or appropriate discharge.<br>-High water consumption for excreta removal.
}}