Changes

Talibon Slaughterhouse Wastewater Retrofit

144 bytes removed, 23:33, 2 September 2016
The Existing Wastewater System
=== The Existing Wastewater System ===
[[File:Talibon.gif|right|200px]]
{| cellspacing="1" cellpadding="1" border="0" style="width: 100%"|-| style="width: 1405px; vertical-align: top" | The system as it is currently installed includes a single chamber digestive tank followed by two open concrete lined pits.The facility layout is represented in the diagram.  The left-most box represents the digestive tank, the middle box represents the first open pit, and the right-most box represents the second open pit. The main concern with the existing layout is that it appears to be too small to accommodate all of the flow and provide the required treatment. Biodigesters that are designed to accomplish anaerobic digestion of slaughterhouse wastewater are generally designed for detention times of between 7 and14 days. Therefore, it appears that the digestive tank is significantly undersized to accomplish complete anaerobic digestion at the design flow. The pits are also on the small size given the projected wastewater flows. They will operate as anaerobic pits, which also require a sufficient detention time to accomplish proper treatment.
| style="width: 216px" | [[File:TalibonThe facility layout is represented in the diagram.gif|  The left-most box represents the digestive tank, the middle box represents the first open pit, and the right|200px]]|}-most box represents the second open pit. The main concern with the existing layout is that it appears to be too small to accommodate all of the flow and provide the required treatment. Biodigesters that are designed to accomplish anaerobic digestion of slaughterhouse wastewater are generally designed for detention times of between 7 and 14 days. Therefore, it appears that the digestive tank is significantly undersized to accomplish complete anaerobic digestion at the design flow. The pits are also on the small size given the projected wastewater flows. They will operate as anaerobic pits, which also require a sufficient detention time to accomplish proper treatment.
=== Wastewater Treatment Concerns ===
Akvopedia-spade, akvouser, bureaucrat, emailconfirmed, staff, susana-working-group-1, susana-working-group-10, susana-working-group-11, susana-working-group-12, susana-working-group-2, susana-working-group-3, susana-working-group-4, susana-working-group-5, susana-working-group-6, susana-working-group-7, susana-working-group-8, susana-working-group-9, susana-working-group-susana-member, administrator, widget editor
30,949
edits