Difference between revisions of "Tertiary Filtration and Disinfection"
(→References) |
|||
(3 intermediate revisions by one other user not shown) | |||
Line 26: | Line 26: | ||
---- | ---- | ||
<br> | <br> | ||
− | |||
[[Image:Icon_anaerobic_filter.png |right|80px]] | [[Image:Icon_anaerobic_filter.png |right|80px]] | ||
Line 68: | Line 67: | ||
===References=== | ===References=== | ||
− | * NWRI (2012). Ultraviolet Disinfection. Guidelines for Drinking Water and Water Reuse. 3rd Ed. National Water Research Institute and Water Research Foundation, Fountain Valley, CA, US. | + | * NWRI (2012). [https://7d22a3c6-d58b-4636-8cac-3260dc7d6552.filesusr.com/ugd/632dc3_c8ab78b05021452c8a520c3b6dba48ca.pdf?index=true Ultraviolet Disinfection. Guidelines for Drinking Water and Water Reuse]. 3rd Ed. National Water Research Institute and Water Research Foundation, Fountain Valley, CA, US. |
− | + | ||
+ | * Robbins, D. M. and Ligon, G.C. (2014). [https://forum.susana.org/comparisons-of-various-wastewater-treatment-types/10768-how-to-design-wastewater-systems-for-local-conditions-in-developing-countries How to Design Wastewater Systems for Local Conditions in Developing Countries]. IWA Publishing, London, UK. | ||
− | * | + | * [http://www.sswm.info/category/implementation-tools/water-purification SSWM Water Purification Tools] SSWM Toolbox. (last accessed February 2021) |
− | * | + | * Tchobanoglous, G., Burton, F. L. and Stensel, H. D. (2004). Wastewater Engineering: Treatment and Reuse, Metcalf & Eddy, 4th Ed. (Internat. Ed.). McGraw-Hill, New York, US. pp. 1035-1330. (Book) |
− | : | ||
− | * | + | * WHO (2006). [https://www.who.int/water_sanitation_health/publications/gsuweg2/en/ Guidelines for the Safe Use of Wastewater, Excreta and Greywater. Volume 2: Wastewater Use in Agriculture]. World Health Organization, Geneva, CH. |
− | * | + | * [http://www.who.int/water_sanitation_health/publications/guidelines-on-sanitation-and-health/en/ WHO: Guidelines on sanitation and health - 2018] |
− | |||
===Acknowledgements=== | ===Acknowledgements=== | ||
{{:Acknowledgements Sanitation}} | {{:Acknowledgements Sanitation}} |
Latest revision as of 04:14, 26 February 2021
|
Depending on the end-use of the effluent or national standards for discharge in water bodies, a post-treatment step may be required to remove pathogens, residual suspended solids and/or dissolved constituents. Tertiary filtration and disinfection processes are most commonly used to achieve this.
Post-treatment is not always necessary and a pragmatic approach is recommended. The effluent quality should match the intended end-use practice or the quality of the receiving water body. The WHO Guidelines for the Safe Use of Wastewater, Excreta and Greywater provide useful information on the assessment and management of risks associated with microbial hazards and toxic chemicals. Among a wide range of tertiary and advanced treatment technologies for effluent, the most widespread include tertiary filtration and disinfection processes.
Contents
Tertiary Filtration
Filtration processes can be classified as either depth (or packed-bed) filtration or surface filtration processes. Depth filtration involves the removal of residual suspended solids by passing the liquid through a filter bed comprised of a granular filter medium (e.g., sand). If activated carbon is used as a filter medium, the dominating process is adsorption. Activated carbon adsorbers not only remove a variety of organic and inorganic compounds, they also eliminate taste and odour. Surface filtration involves the removal of particulate material by mechanical sieving as the liquid passes through a thin septum (i.e., filter layer). Membranes are also surface filters. Low pressure membrane filtration processes (including gravity-driven membrane filters) are being developed. Depth filtration is successfully used to remove protozoan cysts and oocysts, while ultrafiltration membranes can also reliably eliminate bacteria and viruses.
Disinfection
The destruction, inactivation, or removal of pathogenic microorganisms can be achieved by chemical, physical, or biological means. Due to its low cost, high availability and easy operation, chlorine has historically been the disinfectant of choice for treating wastewater. Chlorine oxidizes organic matter, including microorganisms and pathogens. Concerns about harmful disinfection by-products and chemical safety, however, have increasingly led to chlorination being replaced by alternative disinfection systems, such as ultraviolet (UV) radiation and ozonation (O3). UV radiation is found in sunlight and kills viruses and bacteria. Thus, disinfection naturally takes place in shallow ponds (see T.5). UV radiation can also be generated through special lamps, which can be installed in a channel or pipe. Ozone is a powerful oxidant and is generated from oxygen in an energy-intensive process. It degrades both organic and inorganic pollutants, including odour-producing agents. Similar to chlorine, the formation of unwanted by-products is one of the problems associated with the use of ozone as a disinfectant.
Advantages | Disadvantages/limitations |
---|---|
- Additional removal of pathogens and/or chemical contaminants - Allows for direct reuse of the treated wastewater |
- Skills, technology, spare parts and materials may not be locally available - Capital and operating costs can be very high |
Appropriateness
The decision to install a post-treatment technology depends mainly on the quality requirement for the desired end-use of the effluent and/or national standards. Other factors are the effluent characteristics, budget, availability of materials, and O&M capacity. Pathogens tend to be masked by suspended solids in unfiltered secondary effluent. Therefore, a filtration step prior to disinfection brings about much better results with fewer chemicals.
Membrane filters are costly and require expert knowhow for O&M, especially, to avoid damaging the membrane. In activated carbon adsorption the filter material is contaminated after usage and needs proper treatment/disposal. Chlorine should not be used if the water contains significant amounts of organic matter, as disinfection by-products can form. Ozonation costs are generally higher compared to other disinfection methods.
Health Aspects/Acceptance
With both chlorine and ozone disinfection, by-products may form and threaten environmental and human health. There are also safety concerns related to the handling and storage of liquid chlorine. Activated carbon adsorption and ozonation can remove unpleasant colours and odours, increasing the acceptance of reusing reclaimed water.
Operation & Maintenance
All post-treatment methods require continuous monitoring (influent and effluent quality, head loss of filters, dosage of disinfectants, etc.) to ensure a high performance. Due to the accumulation of solids and microbial growth, the effectiveness of sand, membrane and activated carbon filters decreases over time. Frequent cleaning (backwashing) or replacement of the filter material is, therefore, required. For chlorination, trained personnel are required to determine the right dosage of chlorine and ensure proper mixing. Ozone must be generated onsite because it is chemically unstable and rapidly decomposes to oxygen. In UV disinfection, the UV lamp needs regular cleaning and annual replacement.
References
- NWRI (2012). Ultraviolet Disinfection. Guidelines for Drinking Water and Water Reuse. 3rd Ed. National Water Research Institute and Water Research Foundation, Fountain Valley, CA, US.
- Robbins, D. M. and Ligon, G.C. (2014). How to Design Wastewater Systems for Local Conditions in Developing Countries. IWA Publishing, London, UK.
- SSWM Water Purification Tools SSWM Toolbox. (last accessed February 2021)
- Tchobanoglous, G., Burton, F. L. and Stensel, H. D. (2004). Wastewater Engineering: Treatment and Reuse, Metcalf & Eddy, 4th Ed. (Internat. Ed.). McGraw-Hill, New York, US. pp. 1035-1330. (Book)
- WHO (2006). Guidelines for the Safe Use of Wastewater, Excreta and Greywater. Volume 2: Wastewater Use in Agriculture. World Health Organization, Geneva, CH.
Acknowledgements
The material on this page was adapted from:
Elizabeth Tilley, Lukas Ulrich, Christoph Lüthi, Philippe Reymond and Christian Zurbrügg (2014). Compendium of Sanitation Systems and Technologies, published by Sandec, the Department of Water and Sanitation in Developing Countries of Eawag, the Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.
The 2nd edition publication is available in English. French and Spanish are yet to come.