Suitable conditions
This pump is like most of the “Direct Action Pumps” (DAP) limited to pumping lifts of a maximum of 15 m. It is recommended not to go deeper than 12 m.
 
{|border="1" cellpadding="5"
|-
|Depths for use:
|between 0-15 m
|-
|Cylinder diameter:
|50 mm
|-
|Maximum Stroke:
|410 mm
|-
|Approx. discharge (75 watt input):
|at 5 m head: 3 m³/hour<br>
at 10 m head: 1.8 m³/hour<br>
at 15 m head: 1.2 m³/hour
|-
|Pumping lift:
|1 - 15 m
|-
|Population served:
|300 people
|-
|Households:
|30 - 50 hh
|-
|Water cons.:
|15 - 20 lt/per capita
|-
|Type of well:
|borehole or dug well
|}
==Construction, operations and maintenance==
Akvopedia-spade, akvouser, bureaucrat, emailconfirmed, staff, susana-working-group-1, susana-working-group-10, susana-working-group-11, susana-working-group-12, susana-working-group-2, susana-working-group-3, susana-working-group-4, susana-working-group-5, susana-working-group-6, susana-working-group-7, susana-working-group-8, susana-working-group-9, susana-working-group-susana-member, administrator, widget editor